My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7280
Orono
>
Property Files
>
Street Address
>
R
>
Rest Point Circle
>
1354 Rest Point Circle - 07-117-23-32-0062
>
Resolutions
>
Resolution 7280
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:36:01 PM
Creation date
9/30/2022 12:06:50 PM
Metadata
Fields
Template:
x Address Old
House Number
1354
Street Name
Rest Point
Street Type
Circle
Address
1354 Rest Point Cir
Document Type
Resolutions
PIN
0711723320062
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OUTSIDE CORNER <br />ODD COURSE EVEN COURSE <br />ALTERNATE OVERLAP IN CORNERS EVERY COURSE, <br />AS SEEN ABOVE. ADD VERTICAL TIMBER BEHIND <br />THE CORNER IN OUTSIDE CORNERS, AS SEEN ABOVE. <br />inlcinIM rnonlao <br />ALTERNATE OVERLAP IN CORNERS <br />EVERY COURSE, AS SEEN ABOVE. <br />F TIMBER WALL <br />I 1CORNER CONSTRUCTION <br />t)(NOT TO SCALE) <br />WASHER <br />6" X 6" X I" <br />GALVANIZED PLATE <br />NUT <br />MANTA RAY ANCHOR <br />THREADED ROAD (I" DIA) <br />r2 TIMBER WALL <br />ATTACHING GALVANIZED PLATE TO MAN1 <br />W4 (NOT TO SCALE) <br />CONSTRUCTION SEQUENCE: <br />I. CUT HOLES IN THE EXISTING RETAINING WALL LARGE ENOUGH TO INSTALL THE MANTA RAY. <br />2. INSTALL THE MANTA RAYS, TO THE DEPTH SHOWN, AS PER THE MANUFACTURERS <br />RECOMMENDATIONS. <br />3. CONSTRUCT THE TIMBER RETAINING WALL TO IMMEDIATELY BELOW THE MANTA RAY LINE. <br />BACKFILL THE VOID BETWEEN WALLS WITH GRAVEL. <br />4. AFTER CUTTING A HOLE THROUGH THE TIMBERS TO ALLOW THE MANTA RAY THREADED ROD <br />IN PLACE, INSTALL THE NEXT COURSE OF TIMBERS AND NAIL INTO PLACE AS ABOVE. <br />5. INSTALL ADDITIONAL COURSES OF TIMBERS TO THE NEXT MANTA RAY INSTALLATION POINT. 06. INSTALL THE GALVANIZED PLATE USING A GALVANIZED WASHER AND NUT, PER <br />MANUFACTURERS RECOMMENDATIONS. <br />7. CONTINUE THESE STEPS UNTIL THE WALL IS COMPLETED. <br />r3CTIMBER WALL <br />ONSTRUCTION SEQUENCE <br />W4 (NOT TO SCALE) <br />vic6r,q E_nginccring & Consulting, LLLLC <br />i 444 i Village WOOJ5 ]rive <br />E-Jen Prairie, MN 55347 <br />Phone: 952-465-8272 <br />www.vicLer,geng.com <br />O 2022 Vickery Engineering & C,onsulting, LLC <br />PROPOSED TIMBER RETAINING WALLS <br />1354 REST POINT CIRCLE <br />MOUND, MINNESOTA <br />SECTIONS AND DETAILS <br />REV:I DATE: I DESCRIPTION: <br />TIMBER WALL <br />4 TYPICAL CROSS-SECTION AT SECTION CUTS SHOWN <br />W4 (SCALE: 1/4"-1'-0") <br />CALE: 0 1 <br />1 1 <br />AS VERIFY LINE ABOVE MEASURES <br />I -INCH. IF IT DOESN'T, ADJUST <br />SHOWN SCALE ACCORDINGLY <br />VEC PROJECT No: VEC 21-230 <br />DRAWN BY: VEC <br />REVIEWED BY: RWV <br />DATE: 6/4/2022 <br />SHEET: W4 1 /, ICBOU DER CREATIONS UNLIMITE <br />I HEREBY CERTIFY THAT THIS THIS PLAN, SPECIFICATIONS, OR <br />REPORT WAS <br />PZA <br />E BY ME OR ER MY DIRECT <br />SUPERVISION A A DU LICE SEOFESSIONAL <br />ENGINEER D)ilR Sp HE ST E MINNESOTA. <br />r RONALD CKE `GrP <br />DATE: 6/4/ REG. NO.: 24065
The URL can be used to link to this page
Your browser does not support the video tag.