My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7280
Orono
>
Property Files
>
Street Address
>
R
>
Rest Point Circle
>
1354 Rest Point Circle - 07-117-23-32-0062
>
Resolutions
>
Resolution 7280
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:36:01 PM
Creation date
9/30/2022 12:06:50 PM
Metadata
Fields
Template:
x Address Old
House Number
1354
Street Name
Rest Point
Street Type
Circle
Address
1354 Rest Point Cir
Document Type
Resolutions
PIN
0711723320062
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED TIMBER RETAINING WALLS <br />1354 REST POINT CIRCLE <br />MOUND, MINNESOTA <br />GENERAL NOTES <br />1. Soil strength parameters for this project were assumed based on a review of soils viewed by VEC at the project area and information from the client. <br />It is the responsibility of the owner or owner's representative to verify the soil strength parameters provided are representative of the soils available <br />for wall construction. If the soil strength parameters are found to be inconsistent with those used by VEC during the design, this design is no longer <br />valid and it is the responsibility of the owner or owner's representative to notify VEC so the retaining wall system can be redesigned. Failure to <br />notify VEC may result in failure of the retaining wall. <br />2. Design Soil Parameters: <br />a. Retained soil: Imported/on-site clay (CL) phi = 27 degrees gamma = 125 pcf. <br />b. Foundation soil: Imported/on-site clay (CL) phi = 27 degrees gamma = 125 pcf. <br />3. This set of timber retaining wall plans are based on site measurements at the site, as directed by the client. If other plans are produced that contain <br />different information than that referenced, this plan may need to be revised and/or the wall may need to be redesigned. <br />4. This set of timber retaining wall plans are based specifically on the wall being constructed with 6" by 5" timbers and Manta Ray soil anchors. <br />Absolutely no substitutions allowed. <br />5. Location of the timber retaining walls in relation to property lines, utility easements, watershed easements, or any other type of easements are the <br />responsibility of the owner or the site civil engineer. VEC assumes no liability for the location of the retaining wall, or if construction of the proposed <br />retaining wall encroaches any property lines or easements. <br />6. It is imperative that the site surveying of the timber retaining wall be done by the site civil engineer or surveyor and must be based on computer <br />generated site/grading plans and not profile plans done by VEC. Surveying of the retaining wall must take into account the design batter indicated <br />on the enclosed plans and details. Failure to take into account wall batter for timber retaining wall surveying will produce incorrect locations of all <br />top of walls and shall be corrected at no cost to VEC. <br />7. Wall geometry, locations, slopes and surcharge loads for the timber retaining walls were assumed from the information referenced above. If <br />conditions vary greatly in the field from those shown in these plans, VEC must be notified prior to construction of the retaining wall to review the <br />design and/or plans. Modifications to the design and/or plans may be required after the review, and may take up to ten business days to complete. <br />Minor modifications can be made in the field by VEC during construction. <br />8. If there are discrepancies between any information on these plans and information in any project specifications, the more restrictive information <br />takes precedence. Please refer to the Manta Ray installation instructions for additional information. <br />vicLer,q E_ngineering & Consulting, L.L,C <br />i9-441 Village Woods Drive <br />den Prairie, MN 55347 <br />Phone: 952-465-3272 <br />www.vicLeryeng.com <br />2022 Vickery Eof neerina onsultin, <br />PROPOSED TIMBER RETAINING WALLS <br />1354 REST POINT CIRCLE <br />MOUND, MINNESOTA <br />TITLE PAGE AND GENERAL NOTES <br />REV:I DATE: I DESCRIPTION: <br />SHEET INDEX <br />SHEET NO. SHEET DESCRIPTION <br />WI TITLE PAGE & WALL NOTES <br />W2 -W3 WALL ELEVATION VIEWS <br />W4 SECTIONS AND DETAILS <br />SCALE: i w <br />1 SHEET: ' •, <br />I <br />OF: CLIENT: 1 BOULDER CREATIONS UNLIMITE <br />VERIFY LINE ABOVE MEASURES I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATIONS, ORNONEI -INCH. IF IT DOESN'T, ADJUST REPORT WAS PR ARE BY ME OR ER MY DIRECT <br />SCALE ACCORDINGLY SUPERVISION AriRAA A DU LICE SED OFESSIONAL <br />ENGINEER DGSSV HE STMINNESOTA. <br />VEC PROJECT NO VEC 21-230 <br />DRAWN BY: VEC <br />REVIEWED BY: RWV <br />DATE: 1 6/4/2022 <br />RONALD CKE <br />DATE: 6/4/ REG. No.: 24065
The URL can be used to link to this page
Your browser does not support the video tag.