My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 7279
Orono
>
Property Files
>
Street Address
>
R
>
Rest Point Circle
>
1350 Rest Point Circle - 07-117-23-31-0024
>
Resolutions
>
Resolution 7279
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:34:24 PM
Creation date
9/30/2022 11:58:50 AM
Metadata
Fields
Template:
x Address Old
House Number
1350
Street Name
Rest Point
Street Type
Circle
Address
1350 Rest Point Cir
Document Type
Resolutions
PIN
0711723310024
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCHIMNOWSKI <br />CRITERIUM" <br />ENGINEERS <br />June 9, 2022 <br />Revised June 16, 2022) <br />Jared Smith <br />Concept Landscaping <br />PO Box 430 <br />Mound, MN 55364 <br />Submitted by email: JaredMound@aol.com <br />RE: Segmental Retaining Wall Typical Sections <br />Project Location: 1350 Rest Point Circle, Mound, Minnesota <br />Project No. 22-6321 <br />Dear Mr. Smith: <br />This letter includes important details regarding the attached design typical engineered section for the <br />segmental retaining walls at the above location. This design is based on information provided by you in <br />during a site visit on June 2, 2022, including a description of the project and existing site survey and wall <br />layout information. Revisions include changes to the plan view and wall cross-section designs. <br />The attached typical section(s) should be referenced for construction details. Special note should be <br />made of the wall embedment depth and the geosynthetic fabric (geogrid) length as measured from the <br />front face of the wall, or of the no -fines concrete wall backfill material depths, as applicable. Where tree <br />roots conflict with geogrid installation, geogrid lengths may be modified and cut to work around roots. No - <br />fines concrete or double -stacked block walls may also be used as an alternative. Refer to Anchor <br />Retaining Wall Systems Standard Specifications for installation information and details. <br />The design of the wall system assumes the following: <br />Wall location: Replacement of existing timber retaining walls (similar configuration) <br />Wall height(s): 4.67-ft (maximum exposed heights, not including cap units) <br />Minimum embedment depth = 6" min., or as noted <br />Soil conditions: Silty/Clayey Sand, friction angle = 30.0 degrees, unit weight of 125.0 Ib/ft3 <br />Required minimum soil bearing capacity = 1500 psf <br />Surcharge load at top of walls: None <br />2:1 maximum slope at top and bottom of walls <br />Block Type: Anchor Diamond Pro <br />Geosynthetic Fabric Type: Mirafi 3XT <br />Drainage pipe: Required <br />These walls have not been designed for ground water surcharge loads. Direct all surface and <br />groundwater drainage away from the walls. Methods to do so include but are not limited to the following: <br />drainage swale, site grading, retention ponds, etc. Details of water control are left to the wall contractor or <br />the site civil engineer. Please contact Criterium-Schimnowski to provide additional site assessment <br />services if desired. <br />The wall design was performed using the design guidelines presented in the third edition of the "Design <br />Manual for Segmental Retaining Walls" (DMSRW) published by NCMA in 2009. Additional information <br />requested by Criterium-Schimnowski Engineers but not available includes: geotechnical site survey and <br />Independently Owned and Operated <br />161 Dunbar Way / Mahtomedi, MN 55115 <br />O: 651.779.7700 / criterium-schimnowski.com <br />t «1
The URL can be used to link to this page
Your browser does not support the video tag.