Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com 7 <br />SAMPLE <br />SAMPLE PROCEDURES: <br />1. PRIOR TO TAKING SAMPLE HAVE <br />ECOPOD PLANT DISCHARGE <br />EFFLUENT FOR UP TO 4 MINUTES <br />BY FLUSHING TOILETS AND/OR <br />USE GARDEN HOSE TO FLUSH OUT <br />2. INSERT SAMPLE COLLECTING BOTTLE <br />SAMPLE PORT. <br />TO COLLECT ONLY EFFLUENT THAT <br />IS CASCADING OVER THE CASCADING <br />3. HANDLE, STORE, AND TRANSPORT <br />EDGE. <br />AND PROCEDURES PROVIDED BY THE <br />SAMPLES AS SPECIFIED BY POLICIES <br />TESTING LABORATORIES. <br />EFFLUENT SAMPLE PORT <br />AND VENT <br />4" LINE FROM DWELLING <br />PRETREATMENT-TANK REACTOR-TANK <br />ECOPOD REACTOR <br />TO DISCHARGEPOINT OR EFFLUENT <br />REDUCTION SYSTEM <br />BELOWSEE DETAIL <br />CASCADING EDGE <br />4" INLINE CROSS <br />SAMPLE PORT SAMPLE PORT <br />4" INLINE TEE <br />6" PVC RISERW/THRD CAP <br />4" INLET 4" OUTLET <br />RUBBER SEAL <br />MIN 6" <br />PORT DEPTH <br />PIPE OFFSET TOBE 1/2" THEPIPE DIA. <br />MIN. 6" DEPTHPORT <br />(If Applicable) <br />AND VENT AND VENT <br />Figure 1