My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
as-built 11-24-21
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Dr W
>
4780 North Arm Drive West - 06-117-23-23-0012
>
Septic
>
as-built 11-24-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:38 PM
Creation date
9/15/2022 2:08:38 PM
Metadata
Fields
Template:
x Address Old
House Number
4780
Street Name
North Arm
Street Type
Drive
Street Direction
West
Address
4780 North Arm Dr W
Document Type
Septic
PIN
0611723230012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G&B-104 (02/21118) <br />M V011 }.1 <br />CERTIFICATION OF AGGREGATES AND <br />b 4 <br />0 <br />GRANULAR MATERIALS <br />fiy} of Tf1r¢ <br />Project o: <br />Contractors Tester Name: <br />Tim Mueller <br />Tester Certification No (If Required): <br />15465 <br />Submitted y:Fn-meContractor) <br />ubmitted o: (PRO-1ectEngineer) <br />Source or Stockpile Location: <br />Barton Sand & Gravel - 8000 Zachary lane Maple Grove, Mn <br />I certify that these materials to be delivered to this project conform to the appropriate specification requirements. (Type/Print Name) <br />Certified by: (Contractor's Authorized Representative Signature) <br />pate: <br />Pay Item Number <br />Class or Type of <br />Aggregate <br />Quantity <br />Gradation Tests (if required) <br />Required <br />Attached <br />3126 washed sand <br />241 <br />Crushing Tests (N Required) <br />Quality Tests (if Requied) (LAR, Shale, Bitumen, IR, etc.) <br />Required Attached <br />Required <br />Attached <br />Note: <br />NOTE: Attach Required test results (gradations, crushing, bitumen content, qualities, etc.), per <br />the Schedule of Materials Control, plan or proposal, etc. Send cony to Proiect Engineer. <br />Complete below if salvaged/recycled materials are being used: <br />Type or Class of Aggregate Bitumen content of the composite mixture: % <br />Bituminous % Concrete % Glass % <br />Specification Gradation Table for 3138 (3138-3, 3138-0, or 3138-5) <br />Based upon the percentage of recycled material specified above <br />
The URL can be used to link to this page
Your browser does not support the video tag.