My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-24-22 Septic Design
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
555 Ferndale Road North - 36-118-23-14-0003
>
Septic
>
06-24-22 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:01:40 PM
Creation date
9/8/2022 11:40:22 AM
Metadata
Fields
Template:
x Address Old
House Number
555
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
555 Ferndale Road North
Document Type
Septic
PIN
3611823140003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: Multiple tanks or compartments req'd <br />au2h aarger tanK wiui mutupre corner LanKs <br />1000 gallon Dose tank (minimum) at 25.00 gpi <br />29 GPM @ 17 ft. of head, Pump required <br />6.3 inch swing on Demand float which translates to roughly 4.2 inches of float tether length <br />18 inches from bottom of tank to "pump ON" float, orM <br />hours OFF <br />21 inches from bottom of tank to "Hi Level Alarm" or inches to "timer ON" float <br />inches to "Hi level" float <br />45 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />14 inch, or 1.2 ft. Sand Lift Mound <br />10.0 ft, wide by 50.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />20.0 ft.Total sand ABSORPTION width (minimum) <br />O,D ft. upslope and sideslope (sand beyond rockbed, minimum) <br />10.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 8 ft. upslope berm <br />4:1 sideslope 17 ft. sideslope berms <br />3:1 downslope 20 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />L,Upslope berm 0 til b DownslODe berm 20 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.2 11 Clean sand lift <br />1 1.8 Depth to Limiting <br />Limikin$ Condition _ _ ` -- _ — <br />Absorption Width <br />Note. <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes 51 %, A,hsorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 17.0 yd or *1.4= 24 ton 6 inches under pipe <br />Mound Sand: 173 yd or *1.4= 242 ton calculation based on 3:1/4:1 slope from top of rockbe <br />Loamy Cap: 61 yd or *1.4= 85 ton 6" deep <br />Topsoil: 71 yd or *1.4= 99 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />555 rerndale Koaa N. <br />