My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-05-22 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
30 Luce Line Ridge - 31-118-23-34-0011
>
Septic
>
07-05-22 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:41 PM
Creation date
9/6/2022 11:14:06 AM
Metadata
Fields
Template:
x Address Old
House Number
30
Street Name
Luce Line
Street Type
Ridge
Address
30 Luce Line Ridge
Document Type
Septic
PIN
3111823340011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />uu7o Larger WILK wiui muLLipte corner ranres <br />1300 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM' <br />16 ft. of head, Pump required <br />7.8 inch swing on Demand float which translates to roughly 4.9 inches of float tether length <br />if time dosing is required S.b minutes ON time SL ®hours OFF time <br />20 linches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 inches from bottom of tank to "Hi Level Alarm" or 33 inches to -Hi Level alarm" if time dosed <br />70 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />22 inch, or 1.8 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter =ft. long F 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter lx alarm <br />3 clean out i:t valve box assemblies <br />27.0 €t.Total sand ABSORPTION width (minimum) <br />0.0 fit. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed. minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 12 ft. upslope berm <br />4:1 Isidestope 19 ft. sideslope berms <br />3:1 downslope 24 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslo e her12 <br />rn <br />---L� ..----.3I, 1, Dow slope benn- <br />12" cover on sides <br />(6,. loamy cap & b" topsoil) <br />1.8 Clean sand lift <br />1.2 Depth to Limiting <br />t.imitin� Condctfon , ` ` Absorption Width <br />Note: <br />For 4 to 1% slopes, Absorption Width is measured from the Bedecivally in both directions. <br />For slopes >1 %, Absorption Wldth is measured downhill from the upslope edge of the Bed <br />Rock Bed: 21.0 yd3 or *1.4= 29 ton 6 inches under pipe <br />Mound Sand: 271 yd'or *1.4= 379 ton calculation based on 3:1 /4:1 slope from top of rockbe, <br />Loamy Cap: 91 'yd 3 or *1.4= 127 ton 6" deep <br />Topsoil: 104 yd or *1.4= 146 ton 6" deep <br />
The URL can be used to link to this page