My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-05-22 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Luce Line Ridge
>
30 Luce Line Ridge - 31-118-23-34-0011
>
Septic
>
07-05-22 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:41 PM
Creation date
9/6/2022 11:14:06 AM
Metadata
Fields
Template:
x Address Old
House Number
30
Street Name
Luce Line
Street Type
Ridge
Address
30 Luce Line Ridge
Document Type
Septic
PIN
3111823340011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www.SepticResource com (vers 15.2) <br />Property Owner: Joseph Leintz <br />Site Address: 30 Luce Line Ridge <br />Date: 10/20/2017 <br />PID: 3111823340011 <br />Comments: <br />instructions: t = enter data 0 = adjust if desired computer calculated - DO NOT CHANGE! <br />1) bedroom Type Ct Residential System <br />2) 750 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% Larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1.2 GPDIft2 mound sand loading rate contour loading rate of 12 req's a min F62.5ft. long rockbed <br />6) 10,0 ft rockbed width 63.0 ft rockbed length <br />7) 3,0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8) laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total <br />(1 /2 a perf means the first pert starts at the middle feed manifold) <br />9) 7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size I* spacing, Ft pipe size on line 12, max perfs/lateral = 30 line #8 must be less OK <br />10) =doses per day ( 4 minimum) <br />11) 188 gallons per dose (treatment volume) <br />2.00 5x <br />12) F 2.00 inch diameter laterals must be used to meet 'Ax pipe volume" requirement <br />2.00 3x <br />)3) 70 feet of =Inch supply line Leads to12 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />ra) 200 gallons TOTAL pump out volume (treatment + drainback) <br />rs) feet vertical lift pump to mound laterals, leads to a: <br />16) 3b GPM C 16 feet of head, Pump requirement (note: �-50gprn may require an extra 3-6' of head) <br />») 750 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 25.44 Bpi <br />leads to a <br />18) 7.8 inch swing on Demand float, or timed dosing of5.6 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, X70% of Peak design Row) F4 hrs OFF test and adjust as necessary) <br />)9) 12 inches from bottom of tank to "Pump OFF" float <br />20) 20 inches from bottom of tank to "Pump ON" float, or12 inches to "Timer ON" float if time dosed <br />21) 23 inches from bottom of tank to "Hi Level" float, or 33 inches to "Hi Level" float if time dosed <br />22) 664 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.