My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-11-22 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
625 Pinehurst Court - 06-117-23-33-0011
>
Septic
>
07-11-22 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:08 PM
Creation date
9/6/2022 11:03:42 AM
Metadata
Fields
Template:
x Address Old
House Number
625
Street Name
Pinehurst
Street Type
Court
Address
625 Pinehurst Ct
Document Type
Septic
PIN
0611723330011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />OU70 ldfger LanK WWI IVIULLlple comp/WHK5 <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />29 JGPM. @ 20 ft. of head, Pump required <br />6.5 inch swing. on Demand float which translates to roughly 4.3 inches of float tether length <br />I Optional Time dosing of.1 <br />n.i minutes ON <br />19 inches from bottom of tank to "pump ON" float, or 8.5 hours OFF <br />22 inches from bottom of tank to "Hi Level Alarm" or 12 inches to "timer ON" float <br />32 inches to "Hi level" float <br />95 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10.0 ft. wide by 50.0 ft. long Rock bed <br />3 laterals 2,00 inch diameter 48.0 ft. long =ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter it alarm <br />3 clean out Et valve box assemblies <br />27,0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17,0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />4:1 sideslope 18 ft. sideslope berms <br />4:1 downslope 1 30 Ift. downslope berm <br />4" inspection pipe <br />18" cover on top <br />10 <br />berm 1, Downstope ben -n 30 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.7 11 Clean sand lift <br />Depth to Limiting <br />Limiting Condition --------- <br />Absorption Width 27.0-----y�- I-------_ -- _- <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Ahsorptio7 Width is measured downhill from the upslope edge of the Bed <br />Rock Bed: 17.0 yd or *1.4= 24 ton <br />Mound Sand: 263 yd or "1.4= 368 ton <br />Loamy Cap; 84 yd or "1.4= 118 ton <br />Topsoil: 96 yd3 or "1.4= 134 ton <br />INSPECTOR CHECKLIST <br />bLn Ninehurst Court <br />6 inches under pipe <br />calculation based on 3:114:1 slope from top of rockbe <br />6" deep <br />6" deep <br />- mound <br />
The URL can be used to link to this page
Your browser does not support the video tag.