My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-11-22 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
625 Pinehurst Court - 06-117-23-33-0011
>
Septic
>
07-11-22 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:08 PM
Creation date
9/6/2022 11:03:42 AM
Metadata
Fields
Template:
x Address Old
House Number
625
Street Name
Pinehurst
Street Type
Court
Address
625 Pinehurst Ct
Document Type
Septic
PIN
0611723330011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />vuvvrw.SepticResource.com (vers 22.2) <br />Property Owner: Swanson Homes <br />Site Address: 625 Pinehurst Court <br />Comments: <br />Date: 4/5/2022 <br />PID: 0611723330011 <br />instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE! <br />1) bedroom Type �I Residential System <br />2) 600 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s} 1.2 GPD/ftz mound sand loading rate contour loading rate of 12 req's a min 50 ft. long rockbed <br />6) 10.0 ft rockbed width 50.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8) I— ' llaterals 4$.0 feet long 17.0 perfs / lateral F 53 perfs total <br />(1 /2 a pert means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size 6t spacing, it pipe size on line 12, max perfs/lateral ® F370-1, line #8 must be less > OK <br />10) 4.0 doses per day (4 minimum) <br />11) 1 150 gallons per dose (treatment volume) <br />12) 2.Dq inch diameter laterals must be used to meet `°4x pipe volume" requirement <br />13) 95 feet of 2.0 inch supply line leads to16 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 166 gallons TOTAL pump out volume (treatment + drainback) <br />15) 12 feet vertical lift from pump to mound laterals, leads to a: <br />i6) 29 GPM @ 20 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />leads to a: Optional Time dosing of: <br />18) 6.5 inch swing on Demand float, (this delivers Average flow, =70% of Peak design flow) <br />5.7 min ON <br />19)Minches <br />inches from bottom of tank to "Pump OFF" float 8.5 hrs OFF <br />10) inches from bottom of tank to "Pump ON" float 12 inches to "Timer ON" float <br />21) from bottom of tank to "Hi Level" float 32 inches to "Hi Level" float <br />22) 689 gallons reserve capacity (after High Level Alarm is activated -demand dosed) <br />
The URL can be used to link to this page
Your browser does not support the video tag.