My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 longview circle Design2017 with markups
Orono
>
Property Files
>
Street Address
>
L
>
Longview Circle
>
2300 Longview Circle - 03-117-23-23-0018
>
Septic
>
2300 longview circle Design2017 with markups
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:37 PM
Creation date
8/9/2022 10:15:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Longview
Street Type
Circle
Address
2300 Longview Cir
Document Type
Septic
PIN
0311723230018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />1500 gallon Septic tank (minimum) Tank options: none <br />Dine larger tame wttn rnuiupte carne/ tanres <br />500 gallon Dose tank (minimum) at =gpi <br />29 GPM @ =ft. of head, Pump required <br />###### inch swing on Demand float which translates to roughly ##### inches of float tether length <br />if time dosing is required -->4.7 minutes ON time ti ®hours OFF time <br />###### inches from bottom of tank to "pump ON" float, or 1 12 linches to "timer ON" float <br />###### inches from bottom of tank to "Hi Level Alarm" or ##### inches to "Hi level alarm" if time dosed <br />127 ft. of =inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 38.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 36.0 ft. long 3.0 ft. lateral spacing <br />1/4" inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />—3]clean out ft valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sidestope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />3:1 Isidestope 13 Jft. sidestope berms <br />4:1 downslope 1 28 Ift. downslope berm <br />4" inspection pipe <br />1180" cover an top <br />U sla e berm 10 Downslope bene 28 <br />12" cover on sides <br />(6 loamy cap & 6" topsail) <br />1.5 Clean sand lift ��--.�� <br />Depth to Limiting <br />LimitingCondition —-- -----------__— <br />Absorption Width <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absovption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 13.0 yd or*1.4= 18 ton <br />Mound Sand: 161 yd or *1,4= 226 ton <br />Loamy Cap: 59 yd or *1.4= 83 ton <br />Topsoil: 69 yd or *1.4= 97 ton <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe, <br />6" deep <br />6" deep <br />