Laserfiche WebLink
a ' • / 1 � l�� y � � � y <br /> `�� � �� �� REC�11��D <br /> �I.A« � 3 2013 <br /> Joseph Olson D.B.A. crnr oF oRONo <br /> Rusty Olson's--Soil and Percolation Testing " <br /> Joseph J. Olson--MPCA License #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763) 498-8779 fax (763) 498-8290 <br /> January 15,2013 <br /> Ervin Wachman <br /> PID#0611723220018 <br /> Proposed Lot 3 <br /> Orono,Hennepin.County <br /> This on-site Sewage Treatment System is partially designed for a Type 1,five-bedroom home in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> Once the house size,location and septic primary and future sites are chosen this design can be completed. <br /> The periodically saturated soils were located at 14-18 Inches(mottled soil).Due to the periodically <br /> saturated soils,a pressurized mound system will need to be installed to treat the septic effluent. The bottom <br /> of the h�eatment area must be located at least 3' above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 8.4 MPI. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.A filter needs <br /> to be installed on the second tank. Clean outs must be installed on the end of the laterals for maintenance. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area.The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure.A <br /> warning device must be installed with a light and sound device;this is in case of a pump failure. <br /> Use 7/32 inch perforations on the laterals. <br /> Keep all heavy equipmeot off of the proposed treatment areas before and after construction.The <br /> treatment area must be fenced off before construction begins.This Design is not valid&the System <br /> will need to be relocated if failure to protect the areas proposed for the On-Site Sewage Treatment <br /> systems occurs. <br /> Nothing other than gray water,(laundry,showers,ect.)human water&toilet tissue should be disposed of <br /> into the septic tanks.Garbage disposals are not recommended. Additives must not be used;they may cause <br /> harmful damage to your septic system.It is recommended that you pump the septic tank every year for 1 <br /> tank,every two years for two tanks. <br /> Sincerely, <br /> � <br /> �', <br /> -;.- ��.._ ..�-._ _ CITY OF ORONC) <br /> Joseph J.Olson SF.PTIC P MIT `f�EV - <br /> INSPEC O <br /> DAT " PERMIT NQ. <br /> APPROYCD AS 91:I3�tiT7'Ep <br /> � APPROVGp WITH CORRECTtOn9 AS NOTED <br /> NOT APPROVEU-CORRECT&RBSL'6411T <br /> 'Chcse comments are for your informativa. AH work ahaU be doM <br /> fa full compliunce with all applicnble scpdc aed zoninb cucio. <br /> Requirements inc{udittg items not speciiically not�l ip this esvi4111. � F+ � :.;:,;,� <br /> KF:GP THIS PLAAi SfiT OJ�I 9lTb AT ALI.3lM6S f� �� `, � <br /> r <br /> r''� ✓� "� <br /> r__,. � <br />