Laserfiche WebLink
� • r �������� <br /> �� I � r+�� N � �� d �1 I ,3 <br /> JAN �� �Q <br /> � Joseph Olson D.B.A. �����RONO <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MPCA License #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763) 498-8779 fax (763) 498-8290 <br /> January 15,2013 <br /> Ervin Wachman <br /> PID#0611723220018 <br /> Proposed Lotl <br /> Orono,Hennepin.County <br /> This on-site Sewage Treatment System is partially designed for a Type 1,five-bedroom home in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> Once the house size,location and septic primary and future sites are chosen this design can be completed. <br /> The periodically saturated soils were located at 20-28 Inches(mottled soil).Due to the periodically <br /> saturated soils,a pressurized mound system will need to be installed to treat the septic effluent.The bottom <br /> of the treatment area must be located at least 3' above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 6.4 MPI. <br /> The absorption areas are greater than 50 feet from the wetlands. <br /> All tanks need to be insulated if there is less than two feet of cover over the top of the tanks.A filter needs <br /> to be installed on the second tank.Clean outs must be installed on the end of the laterals for maintenance. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area.The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure.A <br /> warning device must be installed with a light and sound device;this is in case of a pump failure. <br /> Use 7/32 inch aerforations on the laterals. <br /> Keep all heavy equipment off of the proposed treatment areas before and after construction.The <br /> treatment area must be fenced off before construction begins.This Design is not valid&the System <br /> will need to be relocated if failure to protect the areas proposed for the On-Site Sewage Treatment <br /> systems occurs. <br /> Nothing other than gray water,(laundry,showers,ect.)human water&toilet rissue should be disposed of <br /> into the septic tanks.Garbage disposals are not recommended.Additives must not be used;they may cause <br /> harmful damage to your septic systern. It is recommended that you pump the septic tank every year for 1 <br /> tank,every two years for two tanks. <br /> CITY OF n[ZO�O <br /> Sincerely, SEPTIC PERM T kEVI <br /> -,>----� <br /> ::. �-._.---..__ INSPECTOR ` <br /> '�� Joseph J.Olson DATE °' PERMIT NO. <br /> APPROVGD AS S�I3�1(TTCU <br /> [] APPROVGD WITH CORRECTIOKS AS NOTBU <br /> Q NOT APPRO�'ED-CORRECT'&RESliByIIT <br /> These camments aro for your information. All work shall be dvrw <br /> in full compliance with all upplicuble septic and�oning code. � <br /> Requirements including items not specificalty nutcJ in this review. ,/ '� �'' �... <br /> KEEP THiS PLAN SET ON S1TE AT ALL TIMES ' �� <br /> �. _;%, � � <br /> . <br />