Laserfiche WebLink
. � °� <br /> , o 0 <br /> � -'"�� � CITYof �RONU <br /> � ��,_� <br /> =-�:::;: <br /> ,� �,��`�:r:-�:=�, �, <br /> '�� 1'.��'-;��i�'`I� �' MunicipalOffices <br /> �., ,: <br /> 'Z �`.' !�������'�G~ Mailing Address: . <br /> !';�,.f,�;.`•� Street Address: <br /> 9k'ESH�4`' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> Owner: Z�v . � Ge����. Address:_ �f 66S �q�S,c�� Rd . <br /> City Ordinance 199 requires that each existing on-site se�vage treatment system in Orono be inspected every two years. <br /> The on-site se�vage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): I <br /> � ��CODE SYSTEM" An ISTS which meets a11 the location,design and construction standards ofthe current Orono bfunicipal Codz. <br /> 2 '�CO�fPLIANT SYSTEM�� An ISTS which does not meet all the locatior�desigt and construction standards ofthe currrnt Orono Municipal <br /> Code but does meet tha three foot sepazation requirement,and which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibitzd ISTS;an ISTS located witfiin a dzsignated 100-yeu flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standazds of the curreat Orono bfuaicipal Code and which is failing for any reason;and <br /> any ISTS�vith less than three feet of unsaturatzd soil or sand between the distribution device and the limiting soil chuacteristics. <br /> TANK CONDITION(5-10): <br /> Tar�inspec[ion indicates: . <br /> � Pumpout not nezdzd at this timz. <br /> � Tanl:must ba pumped out this year (city code rzquires tanks to bz pumpzd out every 3 years. Tank was last pumped 6-�-� � ), <br /> 7 Solids accumul�tion in tanks is at a aitical a critical lzvel. Tanks should be pumped out u soon as possible. <br /> 8 S}stam is discharging to thz surface. Tanks must be pumpzd out within 48 houn to eliminate surface dischargz. <br /> 9 Inspection riszn missing-tanks could no[be inspzeted. Inspection risecs(4"dia.pipe)must be instal(zd in each tank at next pumpout Iftanks <br /> hava not bezn pumpzd out within the last three yeacs,they should be pumped out no�v. <br /> 1� Inspectiun pipe is located directly over tanlc baH1e(does not givz accuratz mzasuremznt of solids accumulation). If tanks have not been pumped <br /> out�vichin the list thrze years,they should be pumped out now. <br /> DRAIVFIELD CO�IDITION(11-14): l� <br /> I 1 DrainField is dry,no surfacing evidznt <br /> 12 Somz e��idcnce oFsurfacing,not critical yet � � ' ' <br /> 13 Drainfizld is satur�tzd and visibly discharging unireated e@luent to the surface. Contacc the City Inspzctor immediataly.Repairs must be <br /> complztzd�rithin 90 days. <br /> 1� Dra'uitield estent and condition unknown <br /> COMI�NTS: S�sfie�. ; S o k . rGn�� :�5pe�r a� �O�es co�l� no-�,- 6� -�oU,.� .� X <br /> p��•p t�•�K �\e��-r:ca\ b�C . <br /> 6-y-�� �� /��-�x��. <br /> Date of Inspection Septic System Inspector ; <br /> Note: In tha event that this inspeccion repoR is used to satisfy the requirements for a moRgage or atfier transfer of property,be advised that this repoR does not guarantee <br /> or certify that an esisting systzm will continua to function properly,but is merely an opinion of the adequacy of the system under current conditions bued on the availab(a <br /> informatioa <br />