Laserfiche WebLink
� O� <br /> I O_i•\ O <br /> } z C ITY of ORONO <br /> �� �'E����j�-� �, <br /> \"�,, V'. �'-.,�'��;;�" ,�lG Municipal Offices <br /> `�.� :,�.,�:,,�.il�:� �a� <br /> � '�',,%'���;,��,���.�� Street Address: Mailing Address: <br /> '�$EggO�' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �O�")►� �r�i �-}-c'�' Address: 4645 Bayside Rd. <br /> Permit #'s: none Dates: Contractors: owner <br /> (This is [ � an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not me=t all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> �^; Non-Com�liant System: System may or may not meet current City standards for design, <br /> Lf construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level [ � has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> 5 Pumpout not needed at this time. <br /> � Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [�/]� were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 12 ' <br /> 11 Drainfield is dry, no surfacing evident. <br /> � Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE• (�ystem age and condition soils etc.) : high <br /> COMMENTS: The drainfield is saturated and slightly surfacing. If the drainfield condition gets <br /> any worse, the system will have to be replaced within 90 days. Also, the system was inspected to <br /> confirm a 3' separation between the drainfield and the seasonal water table. The separation is <br /> 0' and if the system is not discharging to the surface, the s te w, uld need to be replaced by <br /> 12/31/2007. �J���j�� <br /> ./ <br /> Date of Inspection ept' ystem Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />