Laserfiche WebLink
SEPTIC SYSTEM INVENTOR Y <br /> Address: 4565 Bayside Rd. PID: 06-117-23 21 0005 <br /> Building Typ residence #BRs/GPD: 3 #Systems 1 Units Billed 1 <br /> Permit#: 2486 Date of Permit: 11/1/89 Installer: Patnode Bros. <br /> System Type mound Experimental: no Appliances <br /> SYSTEM CONDITION <br /> Confornuty: 1 Tank Condition: 9 DF condition: 11 Failure Pot: low <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000, 1000 <br /> Setback to Bldg: 70 Cesspool: <br /> DRAINFIELD � <br /> Length of Lines 120 # Lines: 3 Trench Width: 10 <br /> Treatment Area: 70*39 Type of Filter rock,clean sand Soil Boring: no <br /> Tile Size: 1.5 Under Tile 9 Perc Rate: 11.2 <br /> Setback DF-Bldg: 120 DF Ht above Wt: 3 <br /> Soil Type: loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File <br /> Pump Type: Depth: Diameter: Method: <br /> INSPECTION RECORD PUMPO UT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 11/1/89 replacement installation 1 9/3/93 1000 <br /> 7/25/91 no surfacing 1 12/8/97 2000 <br /> 8/13/93 no surfacing-pump tanks 1 <br /> 7/29/97 no surfacing-pump tanks 1 <br /> 11/12/99 no surfacing 1 <br />