City of Orono Septic System Approval <br /> ISTS DESIGN <br /> YES NO NA <br /> ISTS design specifications shall include proposed flows or other sizing information, minimum sewage tank <br /> capacity, minimum soil treatment area requirements,a plan of the component layout and all other information <br /> necessary to assure the City that the ISTS is designed and will be constructed to receive,treat and dispose of all <br /> of the sewa e from the buildin served. <br /> Setbacks <br /> Feature Sewa e Tank feet Soil Treatment Area feet <br /> ✓ •• Dee well 50 50 <br /> � Wetland 50 50 <br /> General Develo ment Lake 75 75 <br /> Recreational Develo ment Lake 75 75 <br /> Natural Environment Lake 150 150 <br /> Tributaries/Streams 75 75 <br /> Drivewa s, sidewalks,decks and other hardcover 10 10 <br /> Pro ert lines, buildin s and buried i es 10 20 <br /> • Lawn s rinkler s stems 10 10 <br /> Sewa e Tanks. <br /> r Number of Bedrooms Tanks Liquid Capacities(gallons) <br /> — 4 or less 1,000+ 1,000 re ardless of arba e dis osal use <br /> 5 or 6 1,250+ 1,000 re ardless of arba e dis osal use <br /> �- 7, 8 or 9 1,500+ 1,500 re ardless of arba e dis osal use <br /> — 10 or more Sewa e tanks shall be sized as other establishments er MN Rules 7080. <br /> Pumpin Stations. <br /> In order to standardize installation and electrical connection methods,the following pumping station requirements <br /> must be met in addition to MN Rules cha ter 7080 <br /> Electrical connection: <br /> A waterti ht, lockable electrical box must be mounted on a four-inch b four-inch treated redwood or cedar ost. <br /> � All electrical connections shall be made within the box. Pump connection must not be made using a direct line <br /> lu -in onl . Wire ent to the electrical box shall be sealed with a waterti ht material such as foam or utt . <br /> Alarm and um floats shall be on se arate electrical circuits. <br /> Electrical wire from the power supply must not run over any tanks and must be laid beside the tanks and placed in <br /> conduit alon the electrical ost. <br /> Electrical cords from the pump and floats must be run through a two-inch PVC(or equivalent)conduit(schedule <br /> � 80)with a one-inch gap between the conduit and the electrical box. Electrical cords must not run through or under <br /> the manhole cover. Wires must not have round contact. <br /> Pumpin Chamber: <br /> / Pressure pipe exiting the pumping chamber must be laid on a uniform slope up to the soil treatment area for <br /> �� proper drain back. The pressure pipe must be sleeved and inside a larger diameter pipe for additional support if <br /> spanning ground that has been excavated. If the pipe at the tank must be lower than union to get elevation for <br /> drain back,a one- uarter inch wee hole must be used. <br /> When soil depths above the pressure distribution pipe is less than 3'/z feet, insulation must be added to achieve <br /> an insulating factor equal to 3'/2 feet of soil to decrease the potential for freezing(Styrofoam or concentric piping <br /> are acceptable methods). Piping under hardcover, such as tennis courts or driveways shall be insulated pipe or <br /> e uivalent. <br /> � !�a ti A reserve capacity equaling 75%of the anticipated daily flow must be allowed into the pumping chamber between <br /> 0 the alarm activation level and the um tank inlet. <br /> Protection of drainfield area. <br /> �,� Proposed drainfield areas shall be identified and marked off on the lot at the time of the site evaluation and prior to <br /> �� S � any construction or grading occurring in the area. The drainfield area shall remain undisturbed until drainfield <br /> �t a� �onstruction is commenced. No vehicular traffic shall be allowed in the drainfield area either before or after <br /> b o M•� drainfield installation. <br /> ACCEPTED � DENIED b the Metro West on behalf of the City of Orono subject to existing regulations and the <br /> following conditions: ..�- ..,. � ��.� !�v mu � <br /> � ,,.._ -K .,,.. v- .y+ t s' u � urc 2 <br /> Sr'{�s �'t��: <br /> Inspections required: � � <br /> � 1.�-/��o ,�/. c - Ss � e -.i . <br /> x 2• SAw.e� l� c,fc , ,�. � `' /t rX" .,✓) <br /> 3. i•• r nc ro.,•. 4 R/•4,1..�— c 7� <br /> �I A� �. /t ,6� C's.� ..���s.� <br /> B��i1�,.� .�Gx�•� Printed Name: .0 42�'.V /'f o ���'�✓ Date: 3 J� iS <br /> w:\septic\septic system approval revised 2-2015.docx <br /> Page 2 of 2 <br />