My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
4565 Bayside Road - 06-117-23-21-0010 - New PID
>
Septic
>
Septic design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:46 PM
Creation date
9/8/2015 11:42:56 AM
Metadata
Fields
Template:
x Address Old
House Number
4565
Street Name
Bayside
Street Type
Road
Address
4565 Bayside Rd
Document Type
Septic
PIN
0611723210010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mi�nesota Pollution OSTP Design Summary Worksheet uu�vERs�TY �. �, . <br /> Controt Agency OF �I I�NESOTA � w,�,�_��, <br /> Property OwnerlC(ient: Denali Custom Homes Project ID•�v 06.12.13 <br /> Site Address: 4565 Bayside Road,Orono Date: 2/26/15 <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 260 Gallons Per Day(GPD) Note: The estimated desiyn ffow is considered a penk flow rate <br /> including a safety factor. For(ong ferm performance, the nverage <br /> B. Sepric Tanks: daily flow is recommended to be<60%of this vn(ue. <br /> Minimum Code Required Septic Tank Capacity: 2250 Gallons,in �Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in �Tanks or Compartments <br /> Effluent Screen: Nc q��; No <br /> C. Holding Tanks Only: <br /> Minimum Code Required Capacity:[�Gatlons,in �Tanks <br /> Designer Recommended Capacity:�Gallons,in �Tanks <br /> Type of High Level Alarm: <br /> D, Pump Tank 1 Capacity(Code Minimum):��Gallons Pump Tonk 2 Capacity(Code Minimum): �Gallons <br /> Pump Tank 1 Capaci[y(Designer Rec): �Gallons Pump Tank 2 Capacity(Designer Rec): �Gallons <br /> Pump 1 31.0 GPM Total Head 15.2 ft Pump 2�GPM Total Head �f[ <br /> Supply Pipe Dia. 2.00 in Dose Volume:�gal Supply Pipe Dia.�in Dose Volume:�gal <br /> 2. SYSTEM TYPE <br /> Type of Soil Treatment and Dispersal Ama' <br /> � r Q Gravity Distrb�rtbn v Pressure Distrl��tfon-Level 0 Reswre DistrbirtiondAdevel <br /> � Trmch �Bed �Mound <br /> Q�rip Q Hoidinq Tank C At-Grede 'Selection Required Benchmark Elevation: sea level ft <br /> Benchmark Location: <br /> System Type Type of Distribution Media: <br /> i✓Type I i 'TVpe I I � 'Type II I ,'-Type I V ', Type V OO �rainfield rtodc ❑Registered Treatment Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 24 in 2.0 ft B. Measured Land Slope%: 6.0 % <br /> C. Elevation of Limiting Layer: 1014.8 D. Soil Texture: Clay Loam � <br /> E. Loc.of Restricive Etevation: F. Soil Hyd.Loading Rate: 0.45 GPD/ftZ <br /> G. Minimum Required Separation: 36 in 3.0 ft H. Perc Rate:�MPI <br /> I. Code Maximum Depth of System: mound in Comments: <br /> 4, DESIGN SUAAMARY <br /> Trench Design Summary <br /> Dispersat Area�f� Sidewall Depth�in Trench Width�in <br /> Totat Lineal Feet�ft Number of Trenches� Code Maximum Trench Depth�in <br /> Contour Loading Rate�ft Designers Max Trench Depth�in <br /> Bed Design Summary <br /> Absorption Area�ftz Media Below Pipe�in Code Maximum 8ed Depth�in <br /> Bed Width�ft Bed Length�ft Designers Max Bed Depth�in <br />
The URL can be used to link to this page
Your browser does not support the video tag.