Laserfiche WebLink
A0.1 <br />MAIN LEVEL <br />DEMO PLAN <br />1/4"=1'0" <br />1 <br />A0.1 <br />MAIN LEVEL DEMO PLAN <br />GENERAL DEMOLITION NOTES <br />1. REMOVE ALL EXISTING C ARPET AND PAD IN EFFECT AREAS ONLY, UNLESS OTHERWISE NOTED, BE <br />SURE TO ONLY PULL BACK AND PROTECT EXISTING CARPET IN LOWER LEVEL TO COMPLETE WORK <br />EFFECTIVLY; PAD MATERIAL CAN BE DISCARDED IF NECESSARY. <br />2. REMOVE ALL GYPSUM BOARD ON WALLS AND CEILING PER PLAN. ALL EXISITNG WALL FRAMING TO <br /> REMAIN INTACT UNTIL LOAD BEARING WALLS CAN BE DETERMINED. <br />3. ONCE NON-LOAD BEARING ARE DETERMINED, REMOVE ALL INTERIOR WALLS UNLESS INDICATED <br /> TO REMAIN ON PLAN. <br />4. PROMPTLY REMOVE DEMOLISHED MATERIALS FROM PROPERTY AND LEGALLY DISPOSE OF OFF-SITE. <br />5. PROPERLY PROTECT ALL REMAINING WALLS, CEILINGS, FLOORS, AND EXPOSED FINISHES. <br />6. PROMPTLY PATCH AND REPAIR HOLES AND DAMAGED SURFACES OF BUILDING CAUSED <br /> BY DEMOLITION. RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND <br /> FINISH RESTORATION INTO REMAINING ADJOINING CONSTRUCTION. <br />7. IF MOLD IS PRESENT AT ALL: FOR THE EXISTING WALLS TO REMAIN, REMOVE SURFACE FROM ONE SIDE, <br /> REMOVE INSULATION FROM WALL C AVITIES, CLEAN ALL WALL CAVITY SURFACES, BACK SPRAY <br /> ALL WALL CAVITYSURFACES WITH SEALER , INSTALL NEW CAVITY INSULATION, INSTALL NEW <br /> WALL SURFACE TO MATCH EXISTING. THIS SERVICE IN NOT INCLUDED IN CONTRACT AND WILL <br /> BE BID ON A TIME AND MATERIAL BASIS, IF FOUND AND APPROVED BY HOMEOWNER. <br />8. ANY REMOVEAL OF EXISTING PLUMBING SHOULD BE CAPPED AND PATCHED AS REQUIRED. <br />9. DO NOT INTERRUPT OR DISCONNECT ANY UTILITY OR SERVICE SERVING OCCUPIED PORTIONS OF THE <br />BUILDING WITHOUT PRIOR APPROVAL OF OWNER. <br />10. PERFORM WORK CAREFULLY TO PREVENT HAZARDS TO PERSONS & PROPERTY AND TO AVOID DAMAGE <br />TO SALVAGED MATERIAL BEING REMOVED OR TO EXISTING STRUCTURE, FINISHES, EQUIPMENT, OR <br />SYSTEMS WHICH ARE TO REMAIN. <br />11. PROVIDE TEMPORARY SUPPORT FOR WORK TO REMAIN, IF NECESSARY. <br />12. DO NOT ENDANGER ANY OTHER WORK. <br />13. LIMIT DUST AND DIRT DISPERSAL TO LOWEST PRACTICABLE LEVEL. <br />14. AVOID INTERFERENCE WITH THE USE OF, OR ACCESS TO, ADJACENT SPACES NOT <br />INCLUDED IN THE DEMOLITION AREA. DO NOT RESTRICT ENTRANCES, <br />EXIT WAYS, SIDEWALK, STREET, OR DRIVEWAYS UNLESS PERMISSION IS GIVEN <br />BY THE OWNER OR CITY. <br />PROVIDE A POLY PROTECTION BARRIER TO SEAL OFF UNAFFECTED <br />AREAS AND ALL RETURN AIR VENTS FROM DUST, DEBRIS AND FOREIGN <br />MATERIALS OR AS REQUIRED. <br />KEYED DEMOLITION NOTES <br />REMOVE EXISTING DOOR & FRAME, SALVAGE AND STOCKPILE <br />FOR POSSIBLE REUSE. <br />REMOVE EXISTING WINDOW SASH, FRAME, AND HARDWARE <br />SALVAGE AND STOCKPILE FOR POSSIBLE REUSE. <br />REMOVE EXISTING CEILING FINISH AND GYPSUM BOARD. <br />REMOVE EXISTING WALL FINISH AND GYPSUM BOARD WALLS TO FRAMING. <br />REMOVE EXISTING FLOOR FINISH TO SUB-FLOOR. SALVAGE FOR POSSIBLE REUSE. <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />J <br />REMOVE EXISTING BUILT-IN <br />EXPLORE EXISTING WALL STRUCTURE AND SUPPORT FOR POSSIBLE REMOVAL <br />REMOVE EXISTING PORTION OF WALL.H <br />K <br />L <br />REMOVE EXISTING GYPSUM BOARD SOFFIT, PATCH AND REPAIR AS NEEDED, <br />FIELD VERIFY GYPSUM BOARD THICKNESS TO MATCH, VERIFY FIRE CODE <br />STANDARDS FOR SEPARATION NEEDS <br />REMOVE EXISTING PLUMBING FIXTURES AND PIPES AS NEEDED, CAP AND <br />PATCH AS REQUIRED. STOCKPILE ALL TOILETS FOR POSSIBLE REUSE. <br />REMOVE EXISTING CABINETS PER PLAN, PATCH AND REPAIR AS REQUIRED.M <br />REMOVE EXISTING APPLIANCES OR MECH. EQUIP. PER PLAN, PATCH AND <br />REPAIR AS REQUIRED.N <br />P REMOVE EXISTING CEILING FINISH. VERIFY EXISTING INSULATION IS TO REMAIN <br />WALL & DOOR KEY <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED, <br />UNLESS NOTED OTHERWISE <br />2'0" <br />EXISTING DOOR TO BE REMOVED <br />EXISTING DOOR TO REMAIN <br />NEW OR RELOC ATED DOOR <br />NEW CONCRETE BLOCK FOUNDATION <br />NEW FRAMED WALL/FURRING <br />NORTH <br />1/4"=1'0" <br />1 <br />A0.1 <br />MAIN LEVEL DEMO PLAN <br />APPROX. <br />SKYLIGHT <br />REMOVE EXISTING DECK AND STAIRS <br />REMOVE ENTIRE DOOR/WINDOW AND WALL <br />REMOVE EXISTING FLOOR SYSTEM <br />TO RAISE UP TO ALIGN WITH <br />KITCHEN AND FOYER <br />REMOVE EXISTING <br />MASONRY FIREPLACE <br />REMOVE ALL <br />KITCHEN CABINETS <br />FLOORING AND CEILING <br />REMOVE ALL <br />DASHED WALL <br />LINES, VERIFY BEARING <br />WALLS BEFORE REMOVING <br />W U N D E R L I C H R E S I D E N C E <br />2 7 2 6 C <br />A R O L I N E A V E . <br />O R O N O , M N <br />ISSUE/REVISIONS <br />ISSUE:DATE: <br />THE OWNER &/OR BUILDER (G.C.) IS <br />ACCOUNTABLE FOR ALL DESIGN <br />INTENT, SPECIFICATIONS, STRUCTURES, <br />DETAILS, & FINAL DECISIONS OF <br />ATTACHED DRWINGS. THE DESIGNER <br />SHALL NOT HAVE CONTROL OVER OR <br />CHARGE OF AND SHALL NOT BE <br />RESPONSIBLE FOR FABRICATION <br />TECHNIQUE, METHOD OF <br />INSTALLATION, CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES, <br />SEQUENCES OR PROCEDURES, OR FOR <br />SAFETY PRECAUTIONS AND PROGRAMS <br />IN CONNECTION WITH THE WORK, <br />SINCE THESE ARE SOLELY THE <br />CONTRACTORS &/ OR OWNERS <br />RESPONSIBILITY. <br />Copyright ©2022 JALIN Design, LLC <br />AS-BUILTS 11-18-21 <br />SITE PLAN <br />REVIEW <br />12-15-21 <br />SCHEMATIC <br />DESIGN REVIEW <br />02-15-22 <br />VARIANCE <br />SUBMISSION <br />02-22-22