A0.1
<br />MAIN LEVEL
<br />DEMO PLAN
<br />1/4"=1'0"
<br />1
<br />A0.1
<br />MAIN LEVEL DEMO PLAN
<br />GENERAL DEMOLITION NOTES
<br />1. REMOVE ALL EXISTING C ARPET AND PAD IN EFFECT AREAS ONLY, UNLESS OTHERWISE NOTED, BE
<br />SURE TO ONLY PULL BACK AND PROTECT EXISTING CARPET IN LOWER LEVEL TO COMPLETE WORK
<br />EFFECTIVLY; PAD MATERIAL CAN BE DISCARDED IF NECESSARY.
<br />2. REMOVE ALL GYPSUM BOARD ON WALLS AND CEILING PER PLAN. ALL EXISITNG WALL FRAMING TO
<br /> REMAIN INTACT UNTIL LOAD BEARING WALLS CAN BE DETERMINED.
<br />3. ONCE NON-LOAD BEARING ARE DETERMINED, REMOVE ALL INTERIOR WALLS UNLESS INDICATED
<br /> TO REMAIN ON PLAN.
<br />4. PROMPTLY REMOVE DEMOLISHED MATERIALS FROM PROPERTY AND LEGALLY DISPOSE OF OFF-SITE.
<br />5. PROPERLY PROTECT ALL REMAINING WALLS, CEILINGS, FLOORS, AND EXPOSED FINISHES.
<br />6. PROMPTLY PATCH AND REPAIR HOLES AND DAMAGED SURFACES OF BUILDING CAUSED
<br /> BY DEMOLITION. RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND
<br /> FINISH RESTORATION INTO REMAINING ADJOINING CONSTRUCTION.
<br />7. IF MOLD IS PRESENT AT ALL: FOR THE EXISTING WALLS TO REMAIN, REMOVE SURFACE FROM ONE SIDE,
<br /> REMOVE INSULATION FROM WALL C AVITIES, CLEAN ALL WALL CAVITY SURFACES, BACK SPRAY
<br /> ALL WALL CAVITYSURFACES WITH SEALER , INSTALL NEW CAVITY INSULATION, INSTALL NEW
<br /> WALL SURFACE TO MATCH EXISTING. THIS SERVICE IN NOT INCLUDED IN CONTRACT AND WILL
<br /> BE BID ON A TIME AND MATERIAL BASIS, IF FOUND AND APPROVED BY HOMEOWNER.
<br />8. ANY REMOVEAL OF EXISTING PLUMBING SHOULD BE CAPPED AND PATCHED AS REQUIRED.
<br />9. DO NOT INTERRUPT OR DISCONNECT ANY UTILITY OR SERVICE SERVING OCCUPIED PORTIONS OF THE
<br />BUILDING WITHOUT PRIOR APPROVAL OF OWNER.
<br />10. PERFORM WORK CAREFULLY TO PREVENT HAZARDS TO PERSONS & PROPERTY AND TO AVOID DAMAGE
<br />TO SALVAGED MATERIAL BEING REMOVED OR TO EXISTING STRUCTURE, FINISHES, EQUIPMENT, OR
<br />SYSTEMS WHICH ARE TO REMAIN.
<br />11. PROVIDE TEMPORARY SUPPORT FOR WORK TO REMAIN, IF NECESSARY.
<br />12. DO NOT ENDANGER ANY OTHER WORK.
<br />13. LIMIT DUST AND DIRT DISPERSAL TO LOWEST PRACTICABLE LEVEL.
<br />14. AVOID INTERFERENCE WITH THE USE OF, OR ACCESS TO, ADJACENT SPACES NOT
<br />INCLUDED IN THE DEMOLITION AREA. DO NOT RESTRICT ENTRANCES,
<br />EXIT WAYS, SIDEWALK, STREET, OR DRIVEWAYS UNLESS PERMISSION IS GIVEN
<br />BY THE OWNER OR CITY.
<br />PROVIDE A POLY PROTECTION BARRIER TO SEAL OFF UNAFFECTED
<br />AREAS AND ALL RETURN AIR VENTS FROM DUST, DEBRIS AND FOREIGN
<br />MATERIALS OR AS REQUIRED.
<br />KEYED DEMOLITION NOTES
<br />REMOVE EXISTING DOOR & FRAME, SALVAGE AND STOCKPILE
<br />FOR POSSIBLE REUSE.
<br />REMOVE EXISTING WINDOW SASH, FRAME, AND HARDWARE
<br />SALVAGE AND STOCKPILE FOR POSSIBLE REUSE.
<br />REMOVE EXISTING CEILING FINISH AND GYPSUM BOARD.
<br />REMOVE EXISTING WALL FINISH AND GYPSUM BOARD WALLS TO FRAMING.
<br />REMOVE EXISTING FLOOR FINISH TO SUB-FLOOR. SALVAGE FOR POSSIBLE REUSE.
<br />A
<br />B
<br />C
<br />D
<br />E
<br />F
<br />G
<br />H
<br />J
<br />REMOVE EXISTING BUILT-IN
<br />EXPLORE EXISTING WALL STRUCTURE AND SUPPORT FOR POSSIBLE REMOVAL
<br />REMOVE EXISTING PORTION OF WALL.H
<br />K
<br />L
<br />REMOVE EXISTING GYPSUM BOARD SOFFIT, PATCH AND REPAIR AS NEEDED,
<br />FIELD VERIFY GYPSUM BOARD THICKNESS TO MATCH, VERIFY FIRE CODE
<br />STANDARDS FOR SEPARATION NEEDS
<br />REMOVE EXISTING PLUMBING FIXTURES AND PIPES AS NEEDED, CAP AND
<br />PATCH AS REQUIRED. STOCKPILE ALL TOILETS FOR POSSIBLE REUSE.
<br />REMOVE EXISTING CABINETS PER PLAN, PATCH AND REPAIR AS REQUIRED.M
<br />REMOVE EXISTING APPLIANCES OR MECH. EQUIP. PER PLAN, PATCH AND
<br />REPAIR AS REQUIRED.N
<br />P REMOVE EXISTING CEILING FINISH. VERIFY EXISTING INSULATION IS TO REMAIN
<br />WALL & DOOR KEY
<br />EXISTING TO REMAIN
<br />EXISTING TO BE REMOVED,
<br />UNLESS NOTED OTHERWISE
<br />2'0"
<br />EXISTING DOOR TO BE REMOVED
<br />EXISTING DOOR TO REMAIN
<br />NEW OR RELOC ATED DOOR
<br />NEW CONCRETE BLOCK FOUNDATION
<br />NEW FRAMED WALL/FURRING
<br />NORTH
<br />1/4"=1'0"
<br />1
<br />A0.1
<br />MAIN LEVEL DEMO PLAN
<br />APPROX.
<br />SKYLIGHT
<br />REMOVE EXISTING DECK AND STAIRS
<br />REMOVE ENTIRE DOOR/WINDOW AND WALL
<br />REMOVE EXISTING FLOOR SYSTEM
<br />TO RAISE UP TO ALIGN WITH
<br />KITCHEN AND FOYER
<br />REMOVE EXISTING
<br />MASONRY FIREPLACE
<br />REMOVE ALL
<br />KITCHEN CABINETS
<br />FLOORING AND CEILING
<br />REMOVE ALL
<br />DASHED WALL
<br />LINES, VERIFY BEARING
<br />WALLS BEFORE REMOVING
<br />W U N D E R L I C H R E S I D E N C E
<br />2 7 2 6 C
<br />A R O L I N E A V E .
<br />O R O N O , M N
<br />ISSUE/REVISIONS
<br />ISSUE:DATE:
<br />THE OWNER &/OR BUILDER (G.C.) IS
<br />ACCOUNTABLE FOR ALL DESIGN
<br />INTENT, SPECIFICATIONS, STRUCTURES,
<br />DETAILS, & FINAL DECISIONS OF
<br />ATTACHED DRWINGS. THE DESIGNER
<br />SHALL NOT HAVE CONTROL OVER OR
<br />CHARGE OF AND SHALL NOT BE
<br />RESPONSIBLE FOR FABRICATION
<br />TECHNIQUE, METHOD OF
<br />INSTALLATION, CONSTRUCTION
<br />MEANS, METHODS, TECHNIQUES,
<br />SEQUENCES OR PROCEDURES, OR FOR
<br />SAFETY PRECAUTIONS AND PROGRAMS
<br />IN CONNECTION WITH THE WORK,
<br />SINCE THESE ARE SOLELY THE
<br />CONTRACTORS &/ OR OWNERS
<br />RESPONSIBILITY.
<br />Copyright ©2022 JALIN Design, LLC
<br />AS-BUILTS 11-18-21
<br />SITE PLAN
<br />REVIEW
<br />12-15-21
<br />SCHEMATIC
<br />DESIGN REVIEW
<br />02-15-22
<br />VARIANCE
<br />SUBMISSION
<br />02-22-22
|