Laserfiche WebLink
� O� <br /> �� 0�,,� O <br /> � � T, C ITY of ORONO <br /> \ ) � <br /> � � } ��.j � <br /> ,�� ,�=� � <br /> �', �° �r �� � �!� Municipal Offices <br /> ��,;'�!;r if ' t <br /> �.� '� r��7�`����G Street Address: Mailing Address: <br /> 9$'Egg04' 2150 Keiley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �� ' �" �7 Address: 4465 Bayside Rd. <br /> Permit #'s: none Dates: Contract rs: unknown <br /> (This is [�� an existing system [ ] ne construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds cur nt City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet a 1 current City standards for new construction, but in <br /> most respects appears to be designe , located, and constructed in accordance with previous <br /> � codes and is functioning properly. <br /> ( 3 , Non-Compliant System: System may or may not meet current City standards for design, <br /> �'� construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soi level. <br /> (The saturated soil level [;/] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identif ed, this classification is subject to revision.) <br /> F 5 <br /> 5�' Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicat s they should be pumped out this year. <br /> 7 System is discharging to the surface Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks coul not be inspected. If tanks have not been pumped out <br /> within three years, they should be p mped out and risers installed now. <br /> 9 Inspection pipe is located over tan baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within thre years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ :/J were not confirmed <br /> to be watertight by the licensed pumpin contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subjec to revision.) <br /> DRAINFIELD CONDITION (11-14) : 11 <br /> 11 Drainfield is dry, no surfacing evid nt. <br /> 12 Some evidence of surfacing, not crit cal yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Rep ir must be completed within 90 days. <br /> 14 Drainfield extent and condition unkn wn. <br /> m . ) : medit,m <br /> COMMENTS: In order to confirm that you septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separat on between the drainfield and the seasonal water table. <br /> The separation is .2 feet and the system is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2007. <br /> � <br /> � <br /> Date of Inspection Se ic System Inspector <br /> Note: In the event that this inspecti n report is used to satisfy the requirements for a <br /> transfer of property, this report does ot guarantee that an existing system will continue to <br /> function properly, but indicates the oper tion of the system under current conditions. <br /> Telephone (61 ) 473-7357 • FAX 473-0510 <br />