0 <br /> � � <br /> o , ,, o <br /> � � �-� CI Y of ORONO <br /> � ��� �- <br /> � ��� r r�� � <br /> ��°,�; �►� !�r Municipal Offices <br /> � ��'�� �I� ��� G� <br /> .t � ,�'�.�1���g'�;k� Street Address: Mailing Address: <br /> 'q$EgKO�' 2750 Keiley Park ay P.O. Box 66 <br /> Orono, MN 5535 Crystal Bay, MN 55323-0066 <br /> Owner: _�(i c-(1� �C\�1 h S O %� A dress: 4455 Bayside Rd. <br /> Permit #'s: 1917, 7085 Dates: 8/20/68, 8/3/83 C ntractors: Ed Heins, Widmer Bros. <br /> (This is [xl an existing system [ ] new constructio ) . <br /> SYSTEM COMPLIANCE (1-3) : 1 <br /> � Code System: Meets or exceeds current City sta dards in all respects relating to design, <br /> construction, and location. Appears to be operat'ng properly. <br /> 2 Compliant System: Does not meet all current Ci y standards for new construction, but in <br /> most respects appears to be designed, located, a d constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to p operly treat and dispose of the current <br /> input; and any system with less than three feet o vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level [ x) has or [ ] has no been identified at this time. If the <br /> saturated soil level has not been identified, this clas ification is subject to revision.) <br /> T K N 5 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they shoul be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be ins ected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can ot measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the nks [ ] were or [X] were not coafirmed <br /> to be watertight by the licensed pumping contractor. If the tanka were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 12 <br /> 11 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Re air is not required at this time. <br /> 3 Drainfield is saturated and visibly discharging u treated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be c mpleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> ST M .) : high <br /> COMMENTS: Heavy July rains may be contributing to the drainfield overloading. The discharge is <br /> occurring from the 2nd drop box to the east end of th trench. The owner claims that this line <br /> was abandoned when the trenches were added in 1983. <br /> ����� <br /> Date of Inspection Septic ystem Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the s stem under current conditions. <br /> Telep6one (612) 473-7357 • 473-0510 <br />