Laserfiche WebLink
-- <br /> -- __--� <br /> _ O <br /> � � \ <br /> �, O O\�. <br /> , ��,, ; :� CI Y of ORONO <br /> �, ��^����,�� . l�'� Municipal Offices <br /> � ^,�- �r. �, '�' <br /> � �'�� � � '`"�' � Street Address: Mailing Address: <br /> �'9kEgH04'� 2150 Kelley Parkw y P.O. Box 66 <br /> ��__- Orono, MN 5535 Crystal Bay, MN 55323-0066 <br /> 3 <br /> ���� /yl�� � r� <br /> Owner: �.� �(�.�� 1 �'' Address: 440 Bayside Rd. <br /> E <br /> Permit #'s:1024 Dates:7/19/88 Contractors:K' Mechanical <br /> (This is (� an existing system [ ] new construct'on) <br /> ✓ � <br /> SYSTEM COMPLIANCE (1-3) : 1 <br /> 1 Code Svstem: Meets or exceeds current City tandards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning prope ly. <br /> 3 Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level . <br /> (The saturated soil level � has or [ ] has not b en identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> K CONDITION 5-9 : 5 <br /> 5 Pumpout not needed at this time <br /> � ' Solids accumulation in tanks indicates they hould be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should b pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle- an not measure solids accumulation. If <br /> tanks have not been pumped out within three ears, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout t e tanks [ ] were or [ ] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision. ) <br /> �INFIELD CONDITION (11-14) : 11 <br /> �'17f Drainfield is dry, no surfacing evident. <br /> ��2 Some evidence of surfacing, not critical yet Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharg'ng untreated effluent to the surface. <br /> Contact the City Inspector immediately. Rep ir must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: s stem a e and cond�tion soils etc. : low <br /> COMMENTS: <br /> ��� �'�� ;�.-��/� 2�i � <br /> Date of Inspection ep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarant e that an existing system will continue <br /> to function properly, but indicates the operation f the system under current conditions. <br /> Telephone (612) 473-7357 • X 473-0510 <br />