Septic design - 1990
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4360 Bayside Road - 06-117-23-12-0001
>
Septic
>
Septic design - 1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:10 PM
Creation date
9/2/2015 1:49:26 PM
Metadata
Fields
Template:
x Address Old
House Number
4360
Street Name
Bayside
Street Type
Road
Address
4360 Bayside Rd
Document Type
Septic
PIN
0611723120001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ' S-P TES TI G, INC. <br /> 951 KATYDI� L NE � <br /> ST. MICHAEL, MN 5376 <br /> 497-3566 'b� <br /> Steven B. Sch rmers . <br /> [�9ay 25 . 1990 <br /> Jim Olson � <br /> 4360 Bayside Rd. <br /> Orono , Henn. Co. , MN <br /> This system is Designed for a Type l, �th ee bedroom horre and in accordance <br /> with the Minnesota Pollution Control Age cy Chapter 7080 and local <br /> ordinances . <br /> This site has an existing system with a urface outlet which � s not a <br /> legal system and is considerd a failing ystem. The Olsons bought <br /> the home in the �'all of 85 ' . This syste would have been illegal at <br /> that time also. The soil condidtions wo ld be the same today as <br /> in 1985 . <br /> The soils on this site are typical of SC soils mapped - KkB - Kilkenny <br /> loam. A seasonally high water table was located at 18" , 28" & 30" , <br /> (mottled soil ) . Due to the seasonally h gh water table, a Pressurized .� <br /> Mound System will need to be installed. The bottom of the rock bed <br /> must be located at least 3 ' abov� the se sonally high water table. <br /> The soils at a depth of 12" have a perco ation rate averaging 5 . 4 <br /> min/inch and are adequate for treating s ptic effluent. <br /> A pumping chamber will need to be instal ed to lift the effluent to the <br /> treatment area. <br /> The existing tanks are a block type & wi 1 need to be replaced. Pump <br /> &- fill with soil . � <br /> The manifold and supply line pipe must h ve back drainage to the pumping <br /> chamber. The distribution pipes shall h ve their ends capped. Be sure <br /> the rock and sand fill material are clea . The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches must be lo ated outside the manhole and <br /> pumping chamber in a weather proof enclosure . A• warning device must be <br /> installed with a light and sound device , this is in case of a pump failure. <br /> (Mercury floats are a good method) . <br /> CONT ' D � <br /> Soil and Percolat on Teat: <br /> Septic Syatem esign <br />