My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12-06-2021 Council Packet
Orono
>
City Council
>
2021
>
12-06-2021 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2022 8:10:31 AM
Creation date
1/25/2022 8:02:14 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. CODE: 2018 INTERNATIONAL BUILDING CODE (IBC), AS AMENDED BY THE 2020 MINNESOTA STATE <br />BUILDING CODE (MSBC). <br />2. DESIGN LOADING <br />DEAD LOADS (D) <br />MATERIALS CALCULATED <br />LIVE LOADS (L) <br />FLOOR <br />OFFICE AREA 100 PSF <br />MECHANICAL AREA 300 PSF <br />STAIRS & LANDINGS 100 PSF <br />GRATING & GRATING PLATFORMS 100 PSF <br />EQUIPMENT LIFTING HOOKS 2000 LBS <br />ROOF LIVE LOADS (L/r) <br />UNIFORM 20 PSF <br />EQUIPMENT LIFTING HOOKS 2000 LBS <br />SNOW LOADS (S) <br />Pg GROUND SNOW LOAD 50 PSF <br />Pf FLAT-ROOF SNOW LOAD 42.4 @ ROOF TRUSSES <br />38.5 @ ALL OTHER LOCATIONS <br />Ce SNOW EXPOSURE FACTOR 1.0 <br />Is SNOW LOAD IMPORTANCE FACTOR 1.1 <br />Ct THERMAL FACTOR 1.1 @ ROOF TRUSSES <br />1.0 @ ALL OTHER LOCATIONS <br />Cs SLOPE FACTOR 1.0 <br />pd DRIFT SURCHARGE LOAD(S) XX PSF <br />w WIDTH OF SNOW DRIFTS <br />WIND LOAD (W) <br />V BASIC WIND SPEED 90 MPH (3 SECOND GUST) <br />Vasd ASD WIND SPEED (V*√(0.6)) XX MPH <br />RISK (OCCUPANCY) CATEGORY III <br />EXPOSURE CATEGORY C <br />GCpi INTERNAL PRESSURE COEFFICIENT +/- 0.18 <br />C&C WIND PRESSURE XX PSF <br />EARTHQUAKE (E) <br />RISK (OCCUPANCY) CATEGORY III <br />Ie SEISMIC IMPORTANCE FACTOR X.XX <br />Ss = X.XXg S1 = X.XXg <br />SITE CLASS A <br />SDS = X.XXg SD1 = X.XXg <br />SEISMIC DESIGN CATEGORY C <br />SEISMIC FORCE RESISTING SYSTEM <br />V DESIGN BASE SHEAR XX KIPS <br />CS SEISMIC RESPONSE COEFFICIENT X.XX <br />R RESPONSE MOD. COEFFICIENT X (OR N/A) <br />ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE <br />FLUID (F) <br />WATER 62.4 PCF <br />SLUDGE 70 PCF <br />LATERAL EARTH PRESSURE LOADS (H) <br />DESIGN WATER TABLE 905.0 FEET <br />100-YR. FLOOD ELEVATION NA <br />BACKFILL FRICTION ANGLE 30 DEGREES <br />Ko 0.5 <br />Ka 0.33 <br />Kp 3.0 <br />SOIL UNIT WEIGHT, DRY 120 PCF <br />SURFACE SURCHARGE 300 PSF <br />SOIL - AT REST (ABOVE WATER TABLE) 60 PSF/FT. <br />SOIL - AT REST (BELOW WATER TABLE) NA <br />RAIN (R) <br />i RAIN INTENSITY XX.X IN/HR <br />SPECIAL LOADS (IF APPLICABLE) <br />FLOOD DESIGN DATA (IF APPLICABLE) <br />DESIGN CRITERIA & LOADING <br />1. TYPICAL STRUCTURAL DETAILS AND NOTES SHALL APPLY UNLESS NOTED OTHERWISE ON THE <br />DRAWINGS. <br />2. EXAMINE SITE AND DRAWINGS TO DETERMINE LOCATIONS AND DIMENSIONS OF UTILITIES, AND SITE <br />IMPROVEMENTS. <br />3. BEFORE CONSTRUCTION FABRICATION AND ERECTION OF ANY MATERIALS, CONTRACTOR SHALL FIELD <br />VERIFY ALL EXISTING ELEVATIONS, DIMENSIONS AND CONDITIONS AS SHOWN ON THE DRAWINGS AND <br />REPORT DISCREPANCIES TO THE ENGINEER AT ONCE FOR RESOLUTION. <br />4. ALL DIMENSIONS, LOCATIONS, ELEVATIONS AND CONDITIONS OF EXISTING STRUCTURES SHOWN ON <br />THE CONTRACT DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR. <br />5. THE STRUCTURAL DESIGN IS BASED ONLY ON THE STRUCTURE IN ITS COMPLETED STATE. <br />CONTRACTORS AND THEIR SUBCONTRACTORS SHALL TAKE WHATEVER PRECAUTIONS ARE <br />NECESSARY TO WITHSTAND ALL HORIZONTAL AND VERTICAL LOADING THAT MAY BE ENCOUNTERED <br />DURING THE CONSTRUCTION PROCESS PRIOR TO THE COMPLETION OF THE STRUCTURE. <br />6. ALL MNDOT REFERENCES IN DRAWINGS & SPECIFICATIONS REFER TO THE "STANDARD <br />SPECIFICATIONS FOR CONSTRUCTION", 2018 EDITION. <br />7. WRITTEN DISTANCES & ELEVATIONS SHALL GOVERN OVER SCALED DISTANCES & ELEVATIONS. <br />8. ELEVATIONS ARE BASED ON THE BENCH MARKS NOTED ON THE DRAWINGS. <br />GENERAL NOTES <br />1. LAP SPLICES AND 90 DEGREE END HOOKS SHALL BE AS SHOWN BELOW UNLESS NOTED. WHEN BARS OF <br />TWO DIFFERENT SIZES ARE SPLICED, THE LONGER LAP LENGTH SHALL APPLY. <br /> <br />*TOP BAR LAP SPLICES ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 IN. OF <br />CONCRETE IS CAST IN THE MEMBER BELOW THE SPLICE <br />2. REINFORCING BARS SHALL HAVE THE FOLLOWING CONC. COVER UNLESS NOTED OTHERWISE. <br />FOOTINGS AND OTHER UNFORMED SURFACES 3" <br />CONCRETE EXPOSED TO EARTH, WEATHER OR FLUIDS <br />#6 BARS OR LARGER 2" <br />#5 BARS OR SMALLER 1-1/2" <br />CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND <br />BEAMS, COLUMNS, TIES, SPIRALS AND STIRRUPS 1-1/2" <br />SLABS, WALLS & JOISTS 3/4" <br />3. CONCRETE SHALL BE PLACED WITHOUT CONSTRUCTION JOINTS EXCEPT WHERE SPECIFICALLY SHOWN <br />ON THE DRAWINGS OR AS APPROVED BY THE ENGINEER. <br />4. ALL CONSTRUCTION JOINTS IN WALLS AND SLABS OF LIQUID CONTAINING STRUCTURES SHALL CONTAIN <br />WATERSTOPS. <br />5. CAST-IN-PLACE CONCRETE SHALL NOT BE PLACED IN STANDING WATER, ON FROZEN SOIL OR ON <br />FROZEN CONCRETE. <br />6. FOR LOCATIONS AND DIMENSIONS OF SLEEVES, CURB, OPENINGS AND DEPRESSIONS NOT SHOWN ON <br />THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL, CIVIL/MECHANICAL, YARDWORK, PLUMBING, HVAC <br />AND ELECTRICAL DRAWINGS. CONTRACTOR SHALL VERIFY AND COORDINATE REQUIREMENTS FOR AND <br />LOCATION OF ABOVE ITEMS WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT. <br />7. BEVEL ALL EXPOSED CORNERS OF CONCRETE 3/4" x 3/4". <br />8. PROVIDE WELDED WIRE FABRIC IN FLAT SHEETS. <br />CONCRETE NOTES: <br />F'C=4000 PSI SLAB, WALL, COLUMN BEAM <br />BAR SIZE BAR LAP TOP <br />BAR <br />BAR LAP TOP <br />BAR <br />#3 19 IN. 24 IN. 28 IN. 36 IN. 6 IN. <br />#4 25 IN. 32 IN. 37 IN. 48 IN. 8 IN. <br />#5 31 IN. 40 IN. 46 IN. 60 IN. 10 IN. <br />#6 37 IN. 48 IN. 56 IN. 72 IN. 12 IN. <br />#7 54 IN. 70 IN. 81 IN. 105 IN. 14 IN. <br />#8 62 IN. 80 IN. 93 IN. 120 IN. 16 IN. <br />#9 70 IN. 90 IN. 104 IN. 135 IN. 19 IN. <br />#10 78 IN. 102 IN. 118 IN. 153 IN. 22 IN. <br />#11 87 IN. 113 IN. 131 IN. 170 IN. 24 IN. <br />90 DEGREE <br />HOOK <br />1. THE GEOTECHNICAL ENGINEER SHALL REVIEW AND APPROVE FOUNDATION BEARING SURFACES <br />PRIOR TO THE PLACEMENT OF FOOTINGS OR FOUNDATION. <br />2. DESIGN ALLOWABLE SOIL BEARING PRESSURE = 3,000 PSF <br />3. PROVIDE A MINIMUM OF 3'-6" OF SOIL COVER AT ALL HEATED STRUCTURE EXTERIOR WALL FOOTINGS. <br />PROVIDE A MINIMUM OF 5'-0" OF SOIL COVER AT ALL UNHEATED STRUCTURE FOOTINGS. <br />4. PROTECT FOUNDATION SOILS FROM FREEZING DURING CONSTRUCTION. <br />5. PLACE FILL AND BACKFILL AND COMPACT TO FOLLOWING MAXIMUM STANDARD PROCTOR DENSITIES <br />UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS: <br />LOCATION DENSITY <br />FILL BELOW FOOTINGS 100% <br />FILL BELOW SLABS ON GRADE 98% <br />PIPE AND STRUCTURE EXCAVATIONS 95% <br />GREEN SPACES 90% <br />FOUNDATION AND SOIL NOTES: <br />1. TEMPORARY GROUND CONTROL IS BY CONTRACTOR DESIGN. <br />2. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL TEMPORARY SHEETING AND BRACING NECESSARY <br />TO PROTECT PERSONNEL AND ADJACENT PROPERTY FROM INJURY OR DAMAGE DURING <br />CONSTRUCTION OPERATION. <br />3. EXCAVATIONS OR TRENCHING WITHIN CLOSE PROXIMITY TO UNDERGROUND STRUCTURES, UTILITIES, <br />OR UTILITY POLES WILL REQUIRE PROTECTION AND SUPPORT TO PREVENT DAMAGE OR <br />INTERRUPTION TO SERVICE. THE COST TO PROVIDE THIS PROTECTION SHALL BE INCLUDED IN THE <br />CONTRACTOR'S TOTAL BASE BID PRICE. <br />EXCAVATION NOTES: <br />1. CONCRETE MASONRY UNITS (CMU) AND FACE BRICK SHALL BE LAID IN RUNNING BOND UNLESS NOTED <br />OTHERWISE. <br />2. PROVIDE OPEN-CORE STYLE CMU FOR ALL MASONRY WALLS. <br />3. PROVIDE BULL NOSED CMU FOR ALL INTERIOR EXPOSED MASONRY WALL CORNERS, DOOR JAMBS AND <br />MASONRY OPENINGS UNLESS NOTED OTHERWISE. <br />4. PROVIDE VERTICAL #5 @ 48" REINFORCEMENT FOR ALL WALLS UNLESS NOTED OTHERWISE. <br />5. GROUT FULL ALL CMU CORES CONTAINING VERTICAL REINFORCEMENT. <br />6. INSTALL HORIZONTAL JOINT REINFORCEMENT BETWEEN EVERY OTHER COURSE OF CMU. <br />7. PROVIDE MASONRY CONTROL JOINTS WHERE INDICATED ON THE DRAWINGS OR AT A SPACING OF NOT <br />GREATER THAN 20 FEET. <br />8. TOOL ALL MASONRY JOINTS CONCAVE. <br />9. PROVIDE 16" DEEP LINTEL AT MASONRY OPENINGS 4'-0" AND LESS. PROVIDE 24" DEEP LINTEL AT ALL <br />OPENINGS GREATER THAN 4'-0". PROVIDE (2) #5 IN ALL LINTELS. <br />10. GROUT SOLID ALL BOND BEAMS AND VERTICAL CORES CONTAINING REINFORCEMENT, EMBEDMENTS AND <br />ANCHORS. <br />11. ALL REINFORCING BARS SHALL BE SPLICED WITH A MINIMUM LAP SPLICE EQUAL TO 48 BAR DIAMETERS. <br />MASONRY NOTES: <br />1. PRECAST CONCRETE PLANK SHALL HAVE A 1-HOUR FIRE RATING UNLESS NOTED OTHERWISE. <br />2. VERIFY ALL PLANK PENETRATION SIZES AND LOCATIONS WITH ARCHITECTURAL, MECHANICAL <br />AND ELECTRICAL DRAWINGS. <br />3. PRECAST MANUFACTURER SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL EMBEDMENTS <br />REQUIRED FOR THE ATTACHMENT OF ARCHITECTURAL, MECHANICAL AND ELECTRICAL <br />COMPONENTS. <br />PRECAST CONCRETE PLANK NOTES: <br />REVISIONS <br />DATEN0 BY REMARKS DATEN0 <br />REVISIONS <br />BY REMARKS CHECKED <br />DRAWN <br />DESIGNED <br />PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED <br />DATE REG NOMO <br />D <br />I <br />F <br />I <br />E <br />D <br />: <br />TYPED OR PRINTED NAME: <br />SIGNATURE: <br />FILE NAME <br />PROJECT <br />PL <br />O <br />T <br />T <br />E <br />D <br />: <br />OF <br />2638 SHADOW LANE, SUITE <br />200 <br />CHASKA, MINNESOTA 55318 <br />(952) 448-8838C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />k <br />a <br />i <br />j <br />a <br />\ <br />D <br />r <br />o <br />p <br />b <br />o <br />x <br /> <br />( <br />C <br />R <br />- <br />B <br />P <br />S <br />) <br />\ <br />C <br />R <br />- <br />B <br />P <br />S <br /> <br />T <br />e <br />a <br />m <br /> <br />F <br />o <br />l <br />d <br />e <br />r <br />\ <br />2- <br /> <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br />\ <br />M <br />E <br />T <br />C <br />L <br />0 <br />0 <br />0 <br />5 <br /> <br />- <br /> <br />B <br />M <br />I <br />, <br /> <br />M <br />C <br />E <br />S <br /> <br />L <br />4 <br />9 <br /> <br />L <br />i <br />f <br />t <br /> <br />S <br />t <br />a <br />t <br />i <br />o <br />n <br /> <br />- <br />O <br />r <br />o <br />n <br />o <br />, <br /> <br />M <br />N <br /> <br />- <br /> <br />A <br />r <br />c <br />h <br />\ <br />5 <br />- <br />d <br />s <br />g <br />n <br />\ <br />1 <br />- <br />e <br />x <br />i <br />s <br />t <br />\ <br />2 <br />- <br />b <br />i <br />m <br /> <br />c <br />a <br />d <br />\ <br />M <br />C <br />E <br />S <br /> <br />L <br />4 <br />9 <br />R <br />e <br />v <br />i <br />t <br /> <br />M <br />o <br />d <br />e <br />l <br />\ <br />L <br />i <br />f <br />t <br /> <br />S <br />t <br />a <br />t <br />i <br />o <br />n <br /> <br />2 <br />9 <br /> <br />M <br />o <br />d <br />e <br />l <br /> <br />v <br />2 <br />_ <br />d <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br />. <br />r <br />v <br />t <br />MCES L46 & L49 IMPROVEMENTS <br />STRUCTURAL NOTES <br />802831 SK0.1 <br />Designer <br />Author <br />Checker
The URL can be used to link to this page
Your browser does not support the video tag.