My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
4010 Bayside Road - 06-117-23-11-0007 - New PID
>
4010 Bayside Rd - 06-117-23-11-0006 - Old PID
>
Land Use
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:05 PM
Creation date
8/26/2015 12:44:06 PM
Metadata
Fields
Template:
x Address Old
House Number
4010
Street Name
Bayside
Street Type
Road
Address
4010 Bayside Rd
Document Type
Land Use
PIN
0611723110007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� o� <br /> o :�, o <br /> � �����=- CITY of ORONO <br /> �a �F����� � <br /> r�,� ), �:y'�� ��� �Fr Municipal Offices g <br /> � `�'�` l�'�� G <br /> 9'�`�,':��i�o�g.� Street Address: Mailin Address: <br /> �fEggO 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: l �l'11'S F�✓artiq Address: 4010 Bayside Rd. <br /> Permit #'s: 5433, 1108 Dates: 11/30/78, 7/20/61 Contractors: Arnie Johnson, Bob Benson <br /> (This is [x] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code $ystem: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Com�liant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> �3 Non-Com�liant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level [x] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> �J have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [�] were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> N N 11-14 : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> PnTFNTTAL FOR SYSTEM FAILURE• (system age and condition soils etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2007. <br /> 7��� � � <br /> Date of Inspection Sep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />
The URL can be used to link to this page
Your browser does not support the video tag.