Laserfiche WebLink
DN <br />59 <br />' <br />-0"59 <br />' <br />-0" <br />141'-0" <br />F.E. <br />F.E <br />. <br />F.E. <br />F.E <br />. <br />34'-0"34'-0" <br />121'-0" <br />12 <br />7 <br />' <br />-0" <br />13 <br />1 <br />' <br />-0" <br />129'-0" <br />F.E. <br />F.E <br />. <br />F.E <br />. <br />F.E <br />. <br />F.E. <br />34'-0" <br />121'-0" <br />12 <br />7 <br />' <br />-0" <br />13 <br />1 <br />' <br />-0" <br />129'-0" <br />34'-0" <br />F.E. <br />F.E <br />. <br />F.E <br />. <br />F.E <br />. <br />F.E. <br />102'-0" <br />137'-0"100'-0" <br />87'-0" <br />F.E <br />. <br />F.E <br />. <br />F.E <br />. <br />CODE REVIEW <br />Orono Apartments <br />2745 Kelley Parkway <br />Orono, MN 55356 <br />Project Description: <br />This building is a 56-unit apartment building with enclosed parking. The building generally a two-story building with Four Loft units facing south in roof level. <br />The parking level is constructed with precast wall panels and precast floor panels. The upper floors are wood frame. The building is totally fire sprinkled. <br />Project data is; <br />Parking level 31,692 sf gross <br />First Floor 31,692 sf gross <br />Second Floor 31,692 sf gross <br />Loft Level 10,560 sf gross <br />Total 105,636 sf gross <br />Applicable codes and regulations: <br />• 2015 MN State Building Code (references the 2012 IBC) <br />• 2015 MN Accessibility Code (Chapter1341 references 2009 A117.1) <br />• 2015 MN Comm. Energy Code (references 2012 IECC and ASHREA 90.1) <br />• 2007 MN State Fire Code <br />• 2015 MN Mechanical Code <br />• 2014 MN Electrical Code <br />• 2015 MN Elevator and Related Devices Code <br />Building Classification: <br />USE AND OCCUPANCY CLASSIFICATION (Chapter 3): <br />Dwelling units and related spaces: R-2 (i.e. primary occupancy class) <br />Amenity Spaces <br /> Less than 50 occupants B <br />Parking S-2 <br />Building will be full sprinklered in accordance with NFPA 13 (903.3.1.2) <br />SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCC. (Chapter 4): <br />Parking Garage: <br />a. Min. clear height of 7’0”shall be maintained throughout <br />b. A mechanical ventilation system shall be provided in accordance with the International Mechanical Code. <br />c. All fuel-fired appliances shall be a minimum of 18”above the floor <br />d. Openings from a parking garage directly into a room used for sleeping purposes shall not be permitted. <br />GENERAL BUILDING HEIGHTS AND AREAS (Chapter 5): <br />Type V-A Sprinkled <br />Allowable area & height per table 503; <br />S-2 Type V-A 14,000 sf / 4 stories <br />R-2 Type V-A 12,000 sf / 3 stories <br />Section 506.1 General <br />The building areas limited by Table 503 shall be permitted to be increased due to frontage and automatic sprinkler system protection in accordance with <br />Equation 5-1: <br />Aa = {At + [At x If] + [At x Is]} (Equation 5-1) <br />Aa = 12,000 + [12,000 x .75] + [12,000 x 2] <br />Aa = 12,000 + 9,000 + 24,000 = 45,000 sf/floor for 4 stories <br />x 4 stories = 180,000 sf for building total. <br />The building as proposed is for a floor of a max of 31,692 sf / floor and a building of 2 stories plus a roof level for a building total of 105,636 sf. Both are well <br />within allowances. <br />TYPES OF CONSTRUCTION (Chapter 6): <br />Construction Type Requirements (Type V-A) <br />Primary Structural Frame 1 hour <br />Exterior Bearing Walls 1 hour <br />Interior Bearing Walls 1 hour <br />Interior Non-Bearing Walls 0 hour <br />Floor Construction 1 hour <br />Roof Construction 1 hour <br />FIRE AND SMOKE PROTECTION FEATURES (Chapter 7): <br />Shaft enclosures (Section 713) <br />Connecting less than 4 stories: 1 hour fire resistive rating <br />713.13 Refuse and recycling chutes: <br />Refuse and recycling chute shall not be used for any other purpose in accordance with Section 713.4. Openings into the shaft,including those from access <br />rooms and termination rooms, shall be protected in accordance with this section and Section 716. Openings into chutes shall not be located in corridors. Doors <br />shall be self or automatic closing upon the actuation of a smoke detector in accordance with Section 716.5.9.3, except that heat activated closing devices shall <br />be permitted between the shaft and the termination room. <br />713.13.4 Termination room: <br />Refuse and recycling chutes shall discharge into an enclosed room separated from the remainder of the building by fire barriers constructed in accordance with <br />Section 707. Openings into the termination room shall be protected by opening protectives having a fire protection rating equal to the protection required for the <br />shaft enclosure. Doors shall be self or automatic-closing upon the detection of smoke in accordance with Section716.5.9.3. <br />713.14.1 Elevator Lobby: <br />An enclosed elevator lobby shall be provided at each floor where the elevator shaft enclosure connects more than three stories. The lobby shall separate the <br />elevator shaft enclosure doors from each floor by fire partitions equal to the fire-resistance rating of the corridor and the required opening protection. Elevator <br />lobbies shall have at least one means of egress complying with Chapter 10 and other provisions of this code. <br />Exceptions: <br />1. Enclosed elevator lobbies are not required at the level(s) of exit discharge, provided the level(s) of exit discharge is equipped with an automatic <br />sprinkler system in accordance with Section 903.3.1.1. <br />4. Enclosed elevator lobbies are not required where the building is protected by an automatic sprinkler system installed in accordance with Section <br />903.3.1.1 or 903.3.1.2. <br />Table 716.5 Opening Protective Fire Protection Ratings: <br />Type of Assembly Req’d Assem. Rating Min. Opening Prot. <br />Fire Barriers for required fire-resistant 1 1 <br />Enclosures for shafts, exit access <br />stairways, exit passageways, <br />exit passageway walls. <br />Other Fire Barriers 1 1/4 <br />Fire partitions 0.5 1/3 <br />Corridor Walls 1 1/3 <br />Other fire partitions 0.5 1/3 <br />Exterior Walls 1 3/4 <br />Smoke Barriers 1 1/3 <br />718.4.2 Concealed Spaces Groups R-2: <br />Draftstopping shall be provided in attics, mansards, overhangs or other concealed roof spaces of Group R-2 Building of 3 or more dwelling units. Draftstopping <br />shall be installed above and in line with, sleeping unit and dwelling unit separation walls that do not extend to the underside of the roof sheathing above. <br />Exceptions; <br />1. Where corridor walls provide a sleeping unit or dwelling unit separation, draftstopping shall only be required above one of the corridor walls. <br />2. Draftstopping is not required in buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1. <br />3. In occupancies in Group R-2 that do not exceed four stories above grade, the attic space shall be subdivided by draftstopping into areas not exceeding <br />3,000 sf or above every two dwelling units, whichever is smaller. <br />4. Draftstopping is not required in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.11, provided that <br />automatic sprinklers are also installed in the combustible concealed space where draftstopping is being omitted. <br />INTERIOR FINISHES (Chapter 8): <br />Flame Spread Classification per 803.1.1 <br />Class Flame Spread Index Smoke Developed Index <br />A 0-25 0-450 <br />B 26-75 0-450 <br />C 76-200 0-450 <br />Interior Wall and Ceiling Finish Requirements by Occupancy—Table 803.9 <br />Occupancy Exit Enclosures Corridors Rooms and <br />Group and Passageways Enclosed Spaces <br />R-2 C C C <br />S-2 C C C <br />B B C C <br />Note: Requirements based on fully Sprinklered building. <br />FIRE PROTECTION SYSTEMS (Chapter 9): <br />Group R (903.2.8): <br />An automatic sprinkler system shall be provided throughout the building with a group R fire area. <br />Group S-2 & B Enclosed Parking Area (903.2.10): <br />An Automatic sprinkler system shall be provided in enclosed parking and amenity spaces. <br />Other areas where automatic sprinkler systems are required: (903.2.11.1.3, 903.2.11.2 and 903.2.11.3) Rubbish Chutes <br />Installation Requirements: In accordance with NFPA13 (903.3.1.2) <br />Protection of decks and balconies-decks and balconies greater than 6 feet above grade, greater than 4 feet deep, and with a greater area of 40 sf attached to <br />new Group R-2 occupancy buildings protected in accordance with Section 903.3.1.2 that are three or more stories in height and with 30 or more units shall be <br />protected with sprinklers under the balcony or deck framing and under attic eaves when both of the following two conditions exist; <br />1. The building has an un-sprinklered attic; and <br />2. The building has combustible siding. <br />Standpipe Systems: <br />Standpipes are not required per 905.3.1 as the highest story is not 30 feet above the lowest level of fire department access. <br />Fire Alarm and Detection Systems: <br />Required as per NFPA 72(Section 907) “R-2 Occupancy (907.2.9): Multi-family residential occupancies <br />907.2.11-Single and multiple-station smoke alarms: <br />Listed single-and multiple-station smoke alarms shall be installed in accordance with the provisions of this code and the household fire-warning equipment <br />provisions of NFPA 72. <br />R-2 Occupancies (907.2.11.2.): <br />Single or multiple station smoke alarms shall be installed and maintained regardless of occupant load at all of the following locations on the ceiling or wall <br />outside of each separate sleeping area in the immediate vicinity of bedrooms, in each room for sleeping purposes, and in each story with a dwelling unit. <br />907.2.11.4-Power source: <br />In new construction, required smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source <br />and shall be equipped with a battery backup. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a <br />disconnecting switch other than as required for over current protection. <br />Exception 2: <br />Smoke alarms are not required to be equipped with battery backup in Group R-2 occupancies equipped throughout with an automatic sprinkler system. <br />Carbon Monoxide Alarms: <br />In each dwelling unit provide one carbon monoxide alarm with 10 feet of each room lawfully used for sleeping. <br />MEANS OF EGRESS AND OCCUPANT LOAD (Chapter 10): <br />Occupant Load: <br />Occupant load of this project is: <br />Parking level 31,692 sf gross 159 Occupants (200 sf / occ) <br />First Floor 31,692 sf gross 159 Occupants (200 sf / occ) <br />Second Floor 31,692 sf gross 159 Occupants (200 sf / occ) <br />Loft Level 10,560 sf gross 53 Occupants (200 sf / occ) <br />Total 105,636 sf gross 530 Occupants (200 sf / occ) <br />Egress Width: <br />The total occupant load from the loft level to the first floor (level of exit discharge) is <br />371 (59 + 159 +159) for the corridor width required. <br />The total occupant load from the loft level to the first floor (level of exit discharge) is <br />212 (59 + 159) for the stair width required. <br />Corridor Width Required = 186 (371 occupants divided by 2) x 0.2 = 37.2” <br />Provided is 50” <br />Stair Width Required = 106 per stair (212 occupants divided by 2) x 0.3 = 31.8” <br />Provided is 48”Min. <br />Two Way Communication: <br />Section 1007.8 Two-way communication. A two-way communication system shall be provided at the elevator landing on each <br />accessible floor that is one or more stories above or below the story of exit discharge. <br />Common Path of Egress Travel: <br />Table 1014.3 Common Path of Egress Travel. <br />Occupancy with Sprinkler System <br />B, S-2 100 feet <br />R-2 125 feet <br />According to table 1016.2 Exit Access Travel Distance <br />Occupancy with Sprinkler System <br />R-2 250’ <br />B 300’ <br />S-2 400’ <br />No dead ends greater than 50 feet. <br />The diagram shows the longest distance of travel. <br />ACCESSIBILITY (Chapter 11): <br />2015 Minnesota Accessibility Code <br />Public Common Spaces: Fully accessible as defined by the Minnesota State Accessibility Code and Americans with <br />Disabilities Act (ADA) <br />Dwelling Units (Section 1107.6.2): <br />Type A: 2% of the total of 56 units = 2 dwelling units <br />Type B: All remaining units <br />Accessible Routes; <br />1104.1-At least on accessible route shall be provided from public transportation stops, accessible parking, accessible <br />passenger loading zones and public streets or sidewalks top the accessible building entrance served. <br />1104.4-At least one accessible route shall connect each level in multi-level buildings. <br />Parking; <br />Accessible parking spaces 3 spaces are provided at the accessible entrance. <br />ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15): <br />Table 1505.1 Class “B”required at Type V-A construction <br />ELEVATORS (Chapter 30): <br />Openings protected as per Chapter 7 (3002) <br />Approved signage shall be posted adjacent to each elevator’s call station on each floor. <br />Hoistways of elevators having a travel of 25’or more shall be provided with a means of venting smoke and hot gases to the <br />outer air in case of fire. (3004.1) <br />ENERGY CODE: <br />The building envelope has been designed in compliance with ASHRAE 90.1-2010 utilizing the prescriptive code option. <br />• Roof (insulation entirely above deck)-Average of R-30ci (Minimum) <br />• Metal Framed walls-R-13 +R-7.5ci (or equal) <br />• Mass walls (Parking level)-R-7.5ci <br />• Below Grade walls –R-7.5ci <br />• Unheated slabs R-15 for 24”below <br />• Heated slabs R-20 for 48”below <br />ISSUE DATE: <br />PROJECT NUMBER: <br />2280 Watertown Road, Long Lake, MN 55356-9419 <br />952.476.4434 ·Fax 952.476.5863 · <br />nw@weberarchitects.com© Copyright 2018 Weber Architects & Planners <br />OWNER: <br />4/3/2020 3:23:57 PM <br />ORONO <br />APARTMENTS <br />PERMIT SET <br />Codes Sheet <br />A100.2 <br />Project Number <br />2745 KELLEY <br />PARKWAY ORONO, <br />MN 55356 <br />ORONO APARTMENTS, LLC <br />WAYZATABAY REALTY, <br />3071 LAKE SHORE BLVD. <br />WAYZATA, MN 55391 <br />1" = 30'-0"A300 A100.2 <br />1 Lower Level Codes Plan <br />1" = 30'-0"A300A100.2 <br />2 First Level Codes Plan <br />1" = 30'-0"A300 A100.2 <br />3 Second Level Codes Plan <br />1" = 30'-0"A300 A100.2 <br />4 Loft Level Codes Plan <br />MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT <br />FUNCTION OF SPACE AREA PER OCCUPANT AREA UNIT <br />ACCESSORY STORAGE AND MECH EQUIP ROOMS 300 SF GROSS <br />AGRICULTURAL BUILDING 300 SF GROSS <br />AIRCRAFT HANGERS 500 SF GROSS <br />AIRPORT BAGGAGE CLAIM 20 SF GROSS <br />AIRPORT BAGGAGE HANDLING 300 SF GROSS <br />AIRPORT CONCOURSE 100 SF GROSS <br />AIRPORT WAITING AREAS 15 SF GROSS <br />ASSEMBLY - FIXED SEATING SEE SECTION 1004.6 <br />ASSEMBLY - GAMING FLOOR 11 SF GROSS <br />ASSEMBLY - NON FIXED - CONCENTRATED CHAIRS 7 SF NET <br />ASSEMBLY - NON FIXED - STANDING SPACE 5 SF NET <br />ASSEMBLY - NON FIXED - UNCONCENTRATED 15 SF NET <br />BOWLING CENTERS 7 SF NET <br />BUSINESS AREAS 100 SF GROSS <br />COURTROOMS - OTHER THAN FIXED SEATING 40 SF NET <br />DAYCARE 35 SF NET <br />DORMITORIES 50 SF GROSS <br />EDUCATIONAL - CLASSROOM 20 SF NET <br />EDUCATIONAL - SHOPS & VOCATIONAL 50 SF NET <br />EXERCISE ROOMS 50 SF GROSS <br />H-5 FABRICATION & MANUF. AREAS 200 SF GROSS <br />INDUSTRIAL AREAS 100 SF GROSS <br />INSTITUTIONAL - INPATIENT TREATMENT 240 SF GROSS <br />INSTITUTIONAL - OUTPATIENT AREAS 100 SF GROSS <br />INSTITUTIONAL - SLEEPING AREAS 120 SF GROSS <br />KITCHENS - COMMERCIAL 200 SF GROSS <br />LIBRARY - READING ROOM 50 SF NET <br />LIBRARY - STACK AREA 100 SF GROSS <br />LOCKER ROOMS 50 SF GROSS <br />MERCANTILE - AREAS ON OTHER FLOORS 60 SF GROSS <br />MERCANTILE - BASEMENT & GRADE FLOOR AREAS 30 SF GROSS <br />MERCANTILE - STORAGE, STOCK & SHIPPING 300 SF GROSS <br />PARKING GARAGES 200 SF GROSS <br />RESIDENTIAL 200 SF GROSS <br />SKATING RINK & SWIMMING POOL AREAS 50 SF GROSS <br />SKATING RINK & SWIMMING POOL DECKS 15 SF GROSS <br />STAGES & PLATFORM 15 SF NET <br />WAREHOUSES 500 SF GROSS <br /># REVISION DATE