<br />CODE REVIEW
<br />Orono Apartments
<br />2745 Kelley Parkway
<br />Orono, MN 55356
<br />Project Description:
<br />This building is a 56-unit apartment building with enclosed parking. The building generally a two-story building with Four Loft units facing south in roof level.
<br />The parking level is constructed with precast wall panels and precast floor panels. The upper floors are wood frame. The building is totally fire sprinkled.
<br />Project data is;
<br />Parking level 31,692 sf gross
<br />First Floor 31,692 sf gross
<br />Second Floor 31,692 sf gross
<br />Loft Level 10,560 sf gross
<br />Total 105,636 sf gross
<br />Applicable codes and regulations:
<br />• 2015 MN State Building Code (references the 2012 IBC)
<br />• 2015 MN Accessibility Code (Chapter1341 references 2009 A117.1)
<br />• 2015 MN Comm. Energy Code (references 2012 IECC and ASHREA 90.1)
<br />• 2007 MN State Fire Code
<br />• 2015 MN Mechanical Code
<br />• 2014 MN Electrical Code
<br />• 2015 MN Elevator and Related Devices Code
<br />Building Classification:
<br />USE AND OCCUPANCY CLASSIFICATION (Chapter 3):
<br />Dwelling units and related spaces: R-2 (i.e. primary occupancy class)
<br />Amenity Spaces
<br /> Less than 50 occupants B
<br />Parking S-2
<br />Building will be full sprinklered in accordance with NFPA 13 (903.3.1.2)
<br />SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCC. (Chapter 4):
<br />Parking Garage:
<br />a. Min. clear height of 7’0”shall be maintained throughout
<br />b. A mechanical ventilation system shall be provided in accordance with the International Mechanical Code.
<br />c. All fuel-fired appliances shall be a minimum of 18”above the floor
<br />d. Openings from a parking garage directly into a room used for sleeping purposes shall not be permitted.
<br />GENERAL BUILDING HEIGHTS AND AREAS (Chapter 5):
<br />Type V-A Sprinkled
<br />Allowable area & height per table 503;
<br />S-2 Type V-A 14,000 sf / 4 stories
<br />R-2 Type V-A 12,000 sf / 3 stories
<br />Section 506.1 General
<br />The building areas limited by Table 503 shall be permitted to be increased due to frontage and automatic sprinkler system protection in accordance with
<br />Equation 5-1:
<br />Aa = {At + [At x If] + [At x Is]} (Equation 5-1)
<br />Aa = 12,000 + [12,000 x .75] + [12,000 x 2]
<br />Aa = 12,000 + 9,000 + 24,000 = 45,000 sf/floor for 4 stories
<br />x 4 stories = 180,000 sf for building total.
<br />The building as proposed is for a floor of a max of 31,692 sf / floor and a building of 2 stories plus a roof level for a building total of 105,636 sf. Both are well
<br />within allowances.
<br />TYPES OF CONSTRUCTION (Chapter 6):
<br />Construction Type Requirements (Type V-A)
<br />Primary Structural Frame 1 hour
<br />Exterior Bearing Walls 1 hour
<br />Interior Bearing Walls 1 hour
<br />Interior Non-Bearing Walls 0 hour
<br />Floor Construction 1 hour
<br />Roof Construction 1 hour
<br />FIRE AND SMOKE PROTECTION FEATURES (Chapter 7):
<br />Shaft enclosures (Section 713)
<br />Connecting less than 4 stories: 1 hour fire resistive rating
<br />713.13 Refuse and recycling chutes:
<br />Refuse and recycling chute shall not be used for any other purpose in accordance with Section 713.4. Openings into the shaft,including those from access
<br />rooms and termination rooms, shall be protected in accordance with this section and Section 716. Openings into chutes shall not be located in corridors. Doors
<br />shall be self or automatic closing upon the actuation of a smoke detector in accordance with Section 716.5.9.3, except that heat activated closing devices shall
<br />be permitted between the shaft and the termination room.
<br />713.13.4 Termination room:
<br />Refuse and recycling chutes shall discharge into an enclosed room separated from the remainder of the building by fire barriers constructed in accordance with
<br />Section 707. Openings into the termination room shall be protected by opening protectives having a fire protection rating equal to the protection required for the
<br />shaft enclosure. Doors shall be self or automatic-closing upon the detection of smoke in accordance with Section716.5.9.3.
<br />713.14.1 Elevator Lobby:
<br />An enclosed elevator lobby shall be provided at each floor where the elevator shaft enclosure connects more than three stories. The lobby shall separate the
<br />elevator shaft enclosure doors from each floor by fire partitions equal to the fire-resistance rating of the corridor and the required opening protection. Elevator
<br />lobbies shall have at least one means of egress complying with Chapter 10 and other provisions of this code.
<br />Exceptions:
<br />1. Enclosed elevator lobbies are not required at the level(s) of exit discharge, provided the level(s) of exit discharge is equipped with an automatic
<br />sprinkler system in accordance with Section 903.3.1.1.
<br />4. Enclosed elevator lobbies are not required where the building is protected by an automatic sprinkler system installed in accordance with Section
<br />903.3.1.1 or 903.3.1.2.
<br />Table 716.5 Opening Protective Fire Protection Ratings:
<br />Type of Assembly Req’d Assem. Rating Min. Opening Prot.
<br />Fire Barriers for required fire-resistant 1 1
<br />Enclosures for shafts, exit access
<br />stairways, exit passageways,
<br />exit passageway walls.
<br />Other Fire Barriers 1 1/4
<br />Fire partitions 0.5 1/3
<br />Corridor Walls 1 1/3
<br />Other fire partitions 0.5 1/3
<br />Exterior Walls 1 3/4
<br />Smoke Barriers 1 1/3
<br />718.4.2 Concealed Spaces Groups R-2:
<br />Draftstopping shall be provided in attics, mansards, overhangs or other concealed roof spaces of Group R-2 Building of 3 or more dwelling units. Draftstopping
<br />shall be installed above and in line with, sleeping unit and dwelling unit separation walls that do not extend to the underside of the roof sheathing above.
<br />Exceptions;
<br />1. Where corridor walls provide a sleeping unit or dwelling unit separation, draftstopping shall only be required above one of the corridor walls.
<br />2. Draftstopping is not required in buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1.
<br />3. In occupancies in Group R-2 that do not exceed four stories above grade, the attic space shall be subdivided by draftstopping into areas not exceeding
<br />3,000 sf or above every two dwelling units, whichever is smaller.
<br />4. Draftstopping is not required in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.11, provided that
<br />automatic sprinklers are also installed in the combustible concealed space where draftstopping is being omitted.
<br />INTERIOR FINISHES (Chapter 8):
<br />Flame Spread Classification per 803.1.1
<br />Class Flame Spread Index Smoke Developed Index
<br />A 0-25 0-450
<br />B 26-75 0-450
<br />C 76-200 0-450
<br />Interior Wall and Ceiling Finish Requirements by Occupancy—Table 803.9
<br />Occupancy Exit Enclosures Corridors Rooms and
<br />Group and Passageways Enclosed Spaces
<br />R-2 C C C
<br />S-2 C C C
<br />B B C C
<br />Note: Requirements based on fully Sprinklered building.
<br />FIRE PROTECTION SYSTEMS (Chapter 9):
<br />Group R (903.2.8):
<br />An automatic sprinkler system shall be provided throughout the building with a group R fire area.
<br />Group S-2 & B Enclosed Parking Area (903.2.10):
<br />An Automatic sprinkler system shall be provided in enclosed parking and amenity spaces.
<br />Other areas where automatic sprinkler systems are required: (903.2.11.1.3, 903.2.11.2 and 903.2.11.3) Rubbish Chutes
<br />Installation Requirements: In accordance with NFPA13 (903.3.1.2)
<br />Protection of decks and balconies-decks and balconies greater than 6 feet above grade, greater than 4 feet deep, and with a greater area of 40 sf attached to
<br />new Group R-2 occupancy buildings protected in accordance with Section 903.3.1.2 that are three or more stories in height and with 30 or more units shall be
<br />protected with sprinklers under the balcony or deck framing and under attic eaves when both of the following two conditions exist;
<br />1. The building has an un-sprinklered attic; and
<br />2. The building has combustible siding.
<br />Standpipe Systems:
<br />Standpipes are not required per 905.3.1 as the highest story is not 30 feet above the lowest level of fire department access.
<br />Fire Alarm and Detection Systems:
<br />Required as per NFPA 72(Section 907) “R-2 Occupancy (907.2.9): Multi-family residential occupancies
<br />907.2.11-Single and multiple-station smoke alarms:
<br />Listed single-and multiple-station smoke alarms shall be installed in accordance with the provisions of this code and the household fire-warning equipment
<br />provisions of NFPA 72.
<br />R-2 Occupancies (907.2.11.2.):
<br />Single or multiple station smoke alarms shall be installed and maintained regardless of occupant load at all of the following locations on the ceiling or wall
<br />outside of each separate sleeping area in the immediate vicinity of bedrooms, in each room for sleeping purposes, and in each story with a dwelling unit.
<br />907.2.11.4-Power source:
<br />In new construction, required smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source
<br />and shall be equipped with a battery backup. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a
<br />disconnecting switch other than as required for over current protection.
<br />Exception 2:
<br />Smoke alarms are not required to be equipped with battery backup in Group R-2 occupancies equipped throughout with an automatic sprinkler system.
<br />Carbon Monoxide Alarms:
<br />In each dwelling unit provide one carbon monoxide alarm with 10 feet of each room lawfully used for sleeping.
<br />MEANS OF EGRESS AND OCCUPANT LOAD (Chapter 10):
<br />Occupant Load:
<br />Occupant load of this project is:
<br />Parking level 31,692 sf gross 159 Occupants (200 sf / occ)
<br />First Floor 31,692 sf gross 159 Occupants (200 sf / occ)
<br />Second Floor 31,692 sf gross 159 Occupants (200 sf / occ)
<br />Loft Level 10,560 sf gross 53 Occupants (200 sf / occ)
<br />Total 105,636 sf gross 530 Occupants (200 sf / occ)
<br />Egress Width:
<br />The total occupant load from the loft level to the first floor (level of exit discharge) is
<br />371 (59 + 159 +159) for the corridor width required.
<br />The total occupant load from the loft level to the first floor (level of exit discharge) is
<br />212 (59 + 159) for the stair width required.
<br />Corridor Width Required = 186 (371 occupants divided by 2) x 0.2 = 37.2”
<br />Provided is 50”
<br />Stair Width Required = 106 per stair (212 occupants divided by 2) x 0.3 = 31.8”
<br />Provided is 48”Min.
<br />Two Way Communication:
<br />Section 1007.8 Two-way communication. A two-way communication system shall be provided at the elevator landing on each
<br />accessible floor that is one or more stories above or below the story of exit discharge.
<br />Common Path of Egress Travel:
<br />Table 1014.3 Common Path of Egress Travel.
<br />Occupancy with Sprinkler System
<br />B, S-2 100 feet
<br />R-2 125 feet
<br />According to table 1016.2 Exit Access Travel Distance
<br />Occupancy with Sprinkler System
<br />R-2 250’
<br />B 300’
<br />S-2 400’
<br />No dead ends greater than 50 feet.
<br />The diagram shows the longest distance of travel.
<br />ACCESSIBILITY (Chapter 11):
<br />2015 Minnesota Accessibility Code
<br />Public Common Spaces: Fully accessible as defined by the Minnesota State Accessibility Code and Americans with
<br />Disabilities Act (ADA)
<br />Dwelling Units (Section 1107.6.2):
<br />Type A: 2% of the total of 56 units = 2 dwelling units
<br />Type B: All remaining units
<br />Accessible Routes;
<br />1104.1-At least on accessible route shall be provided from public transportation stops, accessible parking, accessible
<br />passenger loading zones and public streets or sidewalks top the accessible building entrance served.
<br />1104.4-At least one accessible route shall connect each level in multi-level buildings.
<br />Parking;
<br />Accessible parking spaces 3 spaces are provided at the accessible entrance.
<br />ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Chapter 15):
<br />Table 1505.1 Class “B”required at Type V-A construction
<br />ELEVATORS (Chapter 30):
<br />Openings protected as per Chapter 7 (3002)
<br />Approved signage shall be posted adjacent to each elevator’s call station on each floor.
<br />Hoistways of elevators having a travel of 25’or more shall be provided with a means of venting smoke and hot gases to the
<br />outer air in case of fire. (3004.1)
<br />ENERGY CODE:
<br />The building envelope has been designed in compliance with ASHRAE 90.1-2010 utilizing the prescriptive code option.
<br />• Roof (insulation entirely above deck)-Average of R-30ci (Minimum)
<br />• Metal Framed walls-R-13 +R-7.5ci (or equal)
<br />• Mass walls (Parking level)-R-7.5ci
<br />• Below Grade walls –R-7.5ci
<br />• Unheated slabs R-15 for 24”below
<br />• Heated slabs R-20 for 48”below
<br />ISSUE DATE:
<br />PROJECT NUMBER:
<br />2280 Watertown Road, Long Lake, MN 55356-9419
<br />952.476.4434 ·Fax 952.476.5863 ·
<br />nw@weberarchitects.com© Copyright 2018 Weber Architects & Planners
<br />OWNER:
<br />4/3/2020 3:23:57 PM
<br />ORONO
<br />APARTMENTS
<br />PERMIT SET
<br />Codes Sheet
<br />A100.2
<br />Project Number
<br />2745 KELLEY
<br />PARKWAY ORONO,
<br />MN 55356
<br />ORONO APARTMENTS, LLC
<br />WAYZATABAY REALTY,
<br />3071 LAKE SHORE BLVD.
<br />WAYZATA, MN 55391
<br />1" = 30'-0"A300 A100.2
<br />1 Lower Level Codes Plan
<br />1" = 30'-0"A300A100.2
<br />2 First Level Codes Plan
<br />1" = 30'-0"A300 A100.2
<br />3 Second Level Codes Plan
<br />1" = 30'-0"A300 A100.2
<br />4 Loft Level Codes Plan
<br />MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
<br />FUNCTION OF SPACE AREA PER OCCUPANT AREA UNIT
<br />ACCESSORY STORAGE AND MECH EQUIP ROOMS 300 SF GROSS
<br />AGRICULTURAL BUILDING 300 SF GROSS
<br />AIRCRAFT HANGERS 500 SF GROSS
<br />AIRPORT BAGGAGE CLAIM 20 SF GROSS
<br />AIRPORT BAGGAGE HANDLING 300 SF GROSS
<br />AIRPORT CONCOURSE 100 SF GROSS
<br />AIRPORT WAITING AREAS 15 SF GROSS
<br />ASSEMBLY - FIXED SEATING SEE SECTION 1004.6
<br />ASSEMBLY - GAMING FLOOR 11 SF GROSS
<br />ASSEMBLY - NON FIXED - CONCENTRATED CHAIRS 7 SF NET
<br />ASSEMBLY - NON FIXED - STANDING SPACE 5 SF NET
<br />ASSEMBLY - NON FIXED - UNCONCENTRATED 15 SF NET
<br />BOWLING CENTERS 7 SF NET
<br />BUSINESS AREAS 100 SF GROSS
<br />COURTROOMS - OTHER THAN FIXED SEATING 40 SF NET
<br />DAYCARE 35 SF NET
<br />DORMITORIES 50 SF GROSS
<br />EDUCATIONAL - CLASSROOM 20 SF NET
<br />EDUCATIONAL - SHOPS & VOCATIONAL 50 SF NET
<br />EXERCISE ROOMS 50 SF GROSS
<br />H-5 FABRICATION & MANUF. AREAS 200 SF GROSS
<br />INDUSTRIAL AREAS 100 SF GROSS
<br />INSTITUTIONAL - INPATIENT TREATMENT 240 SF GROSS
<br />INSTITUTIONAL - OUTPATIENT AREAS 100 SF GROSS
<br />INSTITUTIONAL - SLEEPING AREAS 120 SF GROSS
<br />KITCHENS - COMMERCIAL 200 SF GROSS
<br />LIBRARY - READING ROOM 50 SF NET
<br />LIBRARY - STACK AREA 100 SF GROSS
<br />LOCKER ROOMS 50 SF GROSS
<br />MERCANTILE - AREAS ON OTHER FLOORS 60 SF GROSS
<br />MERCANTILE - BASEMENT & GRADE FLOOR AREAS 30 SF GROSS
<br />MERCANTILE - STORAGE, STOCK & SHIPPING 300 SF GROSS
<br />PARKING GARAGES 200 SF GROSS
<br />RESIDENTIAL 200 SF GROSS
<br />SKATING RINK & SWIMMING POOL AREAS 50 SF GROSS
<br />SKATING RINK & SWIMMING POOL DECKS 15 SF GROSS
<br />STAGES & PLATFORM 15 SF NET
<br />WAREHOUSES 500 SF GROSS
<br /># REVISION DATE
|