Laserfiche WebLink
�� <br /> .SEPTIC SYSTEM INVENTORY <br /> Address: 3568 Bayside Rd. PID: OS-117-23 13 0041 <br /> Building Type: residence #BRs/GPD 2 Systems/unit 1/1 <br /> Permit#: 7713 Date of Permit: 11/14/84 Installer: Quickway Exc. <br /> System Type: standard trench Appliances: <br /> SYSTEM CONDITION <br /> Conformity: 1 Tank Condition: 9 DF condition: 11 Failure Pot: medium <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000 <br /> Setback to Bldg: 30 <br /> s <br /> > DRAINFIELD <br /> Length of Lines 180 #Lines: 5 Trench Width: 3 <br /> Treatment Area: 550 Type of Filter: rock <br /> Tile Size: 4 Under Tile 12 Perc Rate: 12 <br /> Setback DF-Bldg: 50 DF Ht above Wt: 3 <br /> Soil Type: silt loam, clay loam Limitations: <br /> WELL DATA <br /> Setbacks - Well-Tanks: 50 Well-DF: 50 Report in File: <br /> Pump Type: Depth: Diameter: Method: <br /> INSPECTIONRECORD PUMPOUT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 12/6/82 no surfacing 2 7/7/78 500 <br /> 5/7/84 noted pipe discharging to creek 4 11/8/78 500 <br /> ' 11/16/84 installation-DF undersized,but OK 1* 7/31/79 500 <br /> s <br /> 12/10/84 Plbg. rerouted to new system 1* 10/31/80 2000 � <br /> 8/15/88 no surfacing 1* 11/23/81 1000 <br /> 6/24/91 no surfacing-pump tanks 1* 5/25/82 800 <br /> 7/24/97 no surfacing-hookup by 3/24/98 1* 12/6/94 1500 <br />