My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11-15-2021 Planning Commission Packet
Orono
>
Planning Commission
>
2021
>
11-15-2021 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 8:51:50 AM
Creation date
11/16/2021 8:26:00 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LA21-000070 <br /> November 15,2021 <br /> Page 2 of 4 <br /> Section 78-1403—Structural Building Coverage: • <br /> Total Lot Area Total Structural Coverage <br /> 9,757 sq.ft (0.22 acres) Allowed: 2,000 s.f. <br /> Existing: 0 s.f. (0%) <br /> Proposed: 331 s.f. (3 %) <br /> Section 78-1700—Hardcover Calculations: <br /> Stormwater Total Area in Allowed Existing Proposed <br /> Overlay District Zone Hardcover Hardcover Hardcover <br /> Tier <br /> Tier 1 9,757 s .f. 2,439 s.f. 0 s.f. 2,334 s.f. <br /> (25%) (0%) (23.9%) <br /> Applicable Regulations: <br /> LR-1C, Conditional Uses (Section 78-348) <br /> (7) Public service structures, provided that: <br /> a. All buildings are located at least 50 feet from any adjacent property zoned <br /> for residential use;and <br /> The building is proposed meet the required 50' setback from all residential <br /> properties. <br /> b.The architectural design of the structure is compatible with the <br /> architectural design of the surrounding area. • <br /> The building is bring proposed to have a brick exterior with a gabled roof. (Exhibit D) <br /> Conditional Use Permit (Section 78-916) <br /> The Planning Commission may recommend and the Council may grant a Conditional Use <br /> Permit(CUP) as the use permit was applied for or in modified form. On the basis of the <br /> application and the evidence submitted,the city must find that the proposed use at the <br /> proposed location is or will be: <br /> 1) Consistent with the community management plan; Utility improvements such as lift <br /> stations are consistent with the community management plan. <br /> 2) Compliant with the zoning code, including any conditions imposed on specific uses as <br /> required by article V, division 3 of the City Code; The proposed improvements are <br /> consistent with the City Code;this criterion is met. <br /> 3) Adequately served by police,fire, roads,and stormwater management;This criterion <br /> is met.The applicant proposes removing the existing list station located in the right- <br /> of way and place it in a conforming location within the property boundaries. <br /> 4) Provided with an adequate water supply and sewage disposal system; This is a utility <br /> improvement intended to service the existing sewer infrastructure.This criteria is <br /> met. <br /> 5) Not expected to generate excessive demand for public services at public cost; This <br /> criterion is met. <br /> 6) Compatible with the surrounding area as the area is used both presently and as it is <br /> planned to be used in the future; The proposed building is designed to be • <br />
The URL can be used to link to this page
Your browser does not support the video tag.