My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12-20-2020 Septic Design
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Drive
>
455 North Arm Drive - 06-117-23-31-0018
>
Septic
>
12-20-2020 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:25 PM
Creation date
10/27/2021 2:22:44 PM
Metadata
Fields
Template:
x Address Old
House Number
455
Street Name
North Arm
Street Type
Drive
Address
455 North Arm Dr
Document Type
Septic
PIN
0611723310018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2091 purple code Mound Design <br />www.SepticResource.com (vers 15.2) <br />Property Owner: Swanson Homes <br />Site Address: 455 North Arm Drive <br />Comments: Primary lx Future site <br />Date: 12/14/2020 <br />PID: 0611723310013 <br />instructions: = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />1) F4 bedroom Type Residential System <br />2) b00 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ftz mound sand loading rate contour loading rate of 12 req's a min 50 ft. long rockbed <br />6) 10.0 ft rockbed width 50.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8) 0laterals F48.0 feet long 17.0 perfs / lateral 51 perfs total <br />(1/2 a perf means the first pert starts at the middle feed manifold) <br />9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size Et spacing, Et pipe size on line 12, max perfs/lateral = 30 line #8 must be less --> OK <br />10) 4.0 doses per day (4 minimum) <br />)1) 150 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 80 feet of 2.0 inch supply line leads to =gaLlons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 164 gallons TOTAL pump out volume (treatment + drainback) <br />1s) 20 feet vertical lift from pump to mound laterals, leads to a: <br />16) 29 GPM @ 28 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head') <br />17) 500 gal Dose tank (code minimum) 1DDD gal Dose tank (design size / LUG req'd) at 25.00 gpi <br />Leads to a <br />18) 6.6 inch swing on Demand float, or timed dosing ofMhrs <br />min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) OFF test and adjust as necessary) <br />1g)12 inches from bottom of tank to "Pump OFF" float <br />20) 19 inches from bottom of tank to "Pump ON" float, orF3q2 <br />inches to "Timer ON" float if time dosed <br />21) 22 inches from bottom of tank to `"Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) 45D gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.