My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09-15-2021 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
4085 Watertown Road - 31-118-23-41-0005
>
Septic
>
09-15-2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:31:57 PM
Creation date
10/27/2021 2:18:52 PM
Metadata
Fields
Template:
x Address Old
House Number
4085
Street Name
Watertown
Street Type
Road
Address
4085 Watertown Road
Document Type
Septic
PIN
3111823410005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v 04.01.2020 <br />1. A.Design Flow (Design Sum.1A):GPD C. Tank Use: <br />B. Min. required pump tank capacity: Gal D. Recommended pump tank capacity: Gal <br />2. A. Tank Manufacturer: B. Tank Model: <br />C. Capacity from manufacturer: Gallons <br />D. Gallons per inch from manufacturer: Gallons per inch <br />E. Liquid depth of tank from manufacturer: inches <br />3 <br />(Pump and block height + 2 inches) X Gallons Per Inch <br />(in +2 inches) X Gallons Per Inch =Gallons <br />4 <br /> -Item 18 of the Pressure Distribution or Item 11 of Non-level Gallons (Minimum dose)inches/dose <br />5Calculate Maximum Pumpout Volume (25% of Design Flow) <br />Design Flow: GPD X 0.25 =Gallons (Maximum dose)inches/dose <br />6 Gallons <br />7 Calculate Doses Per Day = Design Flow ÷ Delivered Volume <br />Doses <br />8 Calculate Drainback: <br />A.Diameter of Supply Pipe = inches <br />B. Length of Supply Pipe = feet <br />C.Volume of Liquid Per Lineal Foot of Pipe = Gallons/ft <br />D.Drainback = Length of Supply Pipe X Volume of Liquid Per Lineal Foot of Pipe <br />ft X gal/ft = <br />Gallons <br />9.Total Dosing Volume = Delivered Volume plus Drainback <br />gal + gal = <br />Gallons <br />10. Minimum Alarm Volume = Depth of alarm (2 or 3 inches) X gallons per inch of tank <br />in X gal/in = <br />Gallons <br />DEMAND DOSE FLOAT SETTINGS <br />11. Calculate Float Separation Distance using Dosing Volume . <br />Total Dosing Volume /Gallons Per Inch <br />Inches <br />12.Measuring from bottom of tank: <br />A.Distance to set Pump Off Float = Pump + block height + 2 inches Inches for Dose: 4.2 in <br />Inches Alarm Depth 19.2 in <br />B.Distance to set Pump On Float=Distance to Set Pump-Off Float + Float Separation Distance Pump On 16.2 in 75.0 Gal <br />in + in = <br />Inches Pump Off 12.0 in 106 Gal <br />C.Distance to set Alarm Float = Distance to set Pump-On Float + Alarm Depth (2-3 inches) 300 Gal <br />in + in = <br />Inches <br />10 <br />35 <br />6.0 <br />2 <br />100 <br />600 <br />25.0 <br />2.5 <br />6.0 <br />Select a pumpout volume that meets both Minimum and Maximum: <br />12 <br />gal/in =gal ÷ <br />16 <br />10 12 <br />25.0 <br />Calculate Volume to Cover Pump (The inlet of the pump must be at least 4-inches from the bottom of the pump tank & 2 inches of water covering the pump is <br />recommended) <br />63 <br />4.2 <br />3.0 <br />106 <br />1000 <br />25.0 <br />300 <br />gpd ÷ gal = <br />1916 <br />4.2 <br />75.025.0 <br />106 <br />100 <br />150 <br />35 <br />3 <br />in + 2 in = <br />600 <br />0.170 <br />DETERMINE DOSING VOLUME <br />600 <br />1000 <br />1000 Gallon Pump Tank <br />Note: Design calculations are based on this specific tank. <br />Substituting a different tank model will change the pump <br />float or timer settings. Contact designer if changes are <br />necessary. <br />40.0 <br />6.0 <br />6.00 <br />100 <br />0.170 <br /> Minimum Delivered Volume = 4 X Volume of Distribution Piping: <br />Pump Tank Design Worksheet (Demand Dose) <br />Project ID: DETERMINE TANK CAPACITY AND DIMENSIONS <br />600 Dosing
The URL can be used to link to this page
Your browser does not support the video tag.