Laserfiche WebLink
Prepared by KSD @ 2021 www.ksd‐mn.com Page | 1  <br />SSTS Design Summary Report 9/13/21 <br />On May 5th, 2021, a site evaluation was conducted at 4085 Watertown Road, Orono, MN 55359 to  <br />design a Subsurface Sewage Treatment System (SSTS) for a new 4‐bedroom home. The PID is  <br />3111823410005.  <br />Prior to submitting for permit from City of Orono, please review and sign all pages which require a  <br />signature.  <br />Wastewater Sources & Peak Flow Rate  <br />The expected waste strength is Residential Wastewater with a Peak flow of 600 gallons per day (GPD)  <br />for a 4‐bedroom house.  The Actual Daily Flow should be less than 70% of the Peak Flow (420 GPD).   <br />Type I ‐ Mound  <br />The dispersal area will be a Type I Mound.  The Mound Soil Absorption Area required 1,300 sqft (26’ x  <br />50’).  <br />The minimum required materials for the sewer line, distribution network, pumps, supply line, sand, rock,  <br />fill and cover are detailed in the design worksheets included with this design.   Actual values may change  <br />slightly and will need to be field verified for correctness.  <br />Design Notes  <br />1.Minimum volumes for New Tanks: 1st Tank ‐ 1,250‐gallons; 2nd Tank ‐ 1,000‐gallons; Pump Tank <br />‐ 1,000‐gallons. <br />2.The pump tank will need to installed closer to the mound to create proper drainback. <br />3.An Alternate Site was identified and staked out.  Protect area during construction and for future <br />use. <br />4.Mound berms calculated at 3:1 slope ratio.  The Downslope berm cannot extend beyond <br />property boundary.  Due to the the height of the mound and 12% slope, additional landscaping <br />may be necessary to keep backfill and topsoil on property. <br />5.Alternate Site identified did not find >12" of suitable soil.  The future system will require a Type <br />III mound with 36" of washed mound sand or a Type IV system.  The entire site was investigated <br />for a Type I system for the alternate location.  Due to the vehicle traffic and disturbed soil no <br />secondary site, with a Type I system, can be built on the property. <br />Construction Notes  <br />Building Permit requirements  <br />No construction shall be allowed by any local unit of government until the permit required for the  <br />subsurface sewage treatment system has been issued.   <br />Site Protection  <br />Prior to and during construction or lot improvements, the proposed initial and replacement soil  <br />treatment and dispersal areas shall be protected from disturbance, compaction, or other damage by use  <br />of stakes and silt fence or snow fence.  <br />MR 7080.2100, Subpart 1. F  <br />Electrical installations must comply with applicable laws and ordinances including the most current  <br />codes, rules, and regulations of public authorities having jurisdiction and with part 1315.0200, which  <br />incorporates the National Electrical Code.