My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-29-2021 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
705 Pinehurst Court - 06-117-23-33-0013
>
Septic
>
07-29-2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:11 PM
Creation date
10/27/2021 1:46:12 PM
Metadata
Fields
Template:
x Address Old
House Number
705
Street Name
Pinehurst
Street Type
Court
Address
705 Pinehurst Ct
Document Type
Septic
PIN
0611723330013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: Multiple tanks or compartments req'd <br />7u7o Larger LanK wiLn mutupte compI Lanrt5 <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />36 JGPM @ 22 ft, of head, Pump required <br />7.8 inch swing on Demand float which translates to roughly 4.9 inches of float tether length <br />20 inches from bottom of tank to "pump ON" float, or $.5 hours OFF <br />23 inches from bottom of tank to "Hi Level Alarm" or 12 inches to "timer ON" float <br />33 inches to "Hi level" float <br />67 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10.0 ft, wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out It valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft, upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 1 10 ft. upslope berm <br />3:1 sideslope 1 14 Ift. sideslope berms <br />4:1 downslope 1 30 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslove Berm =_ i , <br />1,7 11 Clean sand lift <br />Downslope berm 30 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />Depth to Limiting <br />Limiting Condition -- ------•-- <br />Absorption Width 27.0 — — ~ — — <br />Note: <br />For 0 to 1% slopes, Absarption Width is measured from the Bedequally in bath directions. <br />For slopes >1%, AbsvrptroI7 Wdth is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 Yd or *1.4= 29 ton <br />Mound Sand: 304 yd or *1.4= 426 ton <br />Loamy Cap: 89 yd3 or *1.4= 125 ton <br />Topsoil: 102 yd or *1.4= 143 ton <br />INSPECTOR CHECKLIST <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe <br />6" deep <br />6" deep <br />- mound <br />
The URL can be used to link to this page
Your browser does not support the video tag.