My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-19-2021 Septic Design
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
2150 Sixth Ave N - 27-117-23-31-0027
>
Septic
>
05-19-2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:19:28 PM
Creation date
10/25/2021 3:55:16 PM
Metadata
Fields
Template:
x Address Old
Address
2150 Sixth Ave N
Document Type
Septic
PIN
2711723310027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G� <br />2011 purple code <br />Property Owner: <br />Mound Design <br />Taryn Hyland <br />www.SepticResource.com (vets 15.2) <br />Date: 12/15/2017 <br />Site Address: Lot2,81k.1,Phillips Woodland Terrace PID: <br />Comments: 3rd Add., Orono <br />instructions: = = enter data = adjust if desired = = computer calculated - DQ NOT CHANGE? <br />l) bedroom Type Residential System <br />2) 750 GPD design flow <br />3) No Garbage disposal or pumped to septic <br />a) 2500 Gat Septic tank (code minimum) 2500 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />5) 1.2 GPD/ft7 mound sand loading rate contour loading rate of 12 red's a min 62.5 ft. long rockbed <br />5) 10.0 ft rockbed width 62.5 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />gl <br />=laterals laterals 60.5 feet long 21.0 perfs / lateral 63 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />inch perfs at feet residual head gives 11.74 gpm flow rate per perforation <br />for this perf size Et spacing, Et pipe size on tine 12, max perfs/lateral = 25-1, line #8 must be less > OK <br />10) 4.D doses per day (4 minimum) <br />l t) 188 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 40 feet of 2.0 inch supply line leads to =gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 195 gallons TOTAL pump out volume (treatment + drainback) <br />ls,) 6 feet vertical lift from pump to mound laterals, leads to a: <br />16) 47 GPM @ 14 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 1250 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 25.Oii gpi <br />leads to a <br />ra) 7.5 inch swing on Demand float, or timed dosing of4.1 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)hrs OFF test and adjust as necessary) <br />14) 12 inches from bottom of tank to "pump OFF' float <br />20) 20 linches from bottom of tank to "Pump ON" float, orP33] <br />inches to 'Timer ON" float if time dosed <br />yl) 23 inches from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />'.a) 652 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.