2021 Septic Design
Orono
>
Property Files
>
Street Address
>
S
>
Stubbs Bay Road North
>
015 Stubbs Bay Road North - 32-118-23-34-0006
>
Septic
>
2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:54 PM
Creation date
10/21/2021 9:35:58 AM
Metadata
Fields
Template:
x Address Old
House Number
15
Street Name
Stubbs Bay
Street Type
Road
Street Direction
North
Address
15 Stubbs Bay Road North
Document Type
Septic
PIN
3211823340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />W70 targer LanK wiin rnutuipte comp/ tanKs <br />1250 gallon Dose tank (minimum) at 25,48 gpi <br />29 JGPM @ 14 ft. of head, Pump required <br />6.0 inch swing on Demand float which translates to roughly =inches of float tether length <br />Optional Time dosing of: <br />18 inches from bottom of tank to "pump ON" float, orM <br />hours OFF <br />21 inches from bottom of tank to "Hi Level Alarm" or inches to "timer ON" float <br />inches to "Hi level" float <br />15 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />24 inch, or 2.0 ft. Sand Lift Mound <br />10.0 ft. wide by 50.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No JEffluent filter Et alarm <br />3 clean out Et valve box assemblies <br />20.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />10.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />3:1 sideslope 17 ft. sideslope berms <br />4:1 downslope 1 34 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />berm 10 .I 1� L, Downstope berm 34 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />2.0 11 Clean sand lift <br />_ <br />Depth to Limiting <br />__ng Co1.0 <br />Limitindition _ — ---�_ --d _a __ <br />Absorption Width 20.0 — —_— _ �----__---_—_ <br />Neste: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1 , Absorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 17.0 yd3 or *1.4= 24 ton <br />Mound Sand: 340 yd or *1.4= 475 ton <br />Loamy Cap: 89 yd or *1.4= 125 ton <br />Topsoil: 101 yd or *1.4= 141 ton <br />INSPECTOR CHECKLIST <br />6 inches under pipe <br />calculation based on 3:1 /4:1 slope from top of rockbe <br />6" deep <br />6" deep <br />- mound <br />