My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021 Septic Design
Orono
>
Property Files
>
Street Address
>
S
>
Stubbs Bay Road North
>
015 Stubbs Bay Road North - 32-118-23-34-0006
>
Septic
>
2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:54 PM
Creation date
10/21/2021 9:35:58 AM
Metadata
Fields
Template:
x Address Old
House Number
15
Street Name
Stubbs Bay
Street Type
Road
Street Direction
North
Address
15 Stubbs Bay Road North
Document Type
Septic
PIN
3211823340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purpte code Mound Design <br />vwww.SepticResource.eom (vers 19.2) <br />Property Owner: Mary Dunn Trust <br />Site Address: 15 Stubbs Bay Road N. <br />Comments: <br />Date: 5/1/2021 <br />PID: 3211823340006 <br />instructions: u = enter data = adjust if desired = = computer calculated - DO NOT CHANGE! <br />1) bedroom Type �I Residential System <br />2) 600 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 225p Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1,2 GPD/ft2 mound sand loading rate contour loading rate of =req's a min 50 ft. long rockbed <br />b) 10.0 ft rockbed width 50.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8) laterals 48.0 feet long 17.0 perfs / lateral 51 perfs total <br />(1 /2 a perf means the first pert starts at the middle feed manifold) <br />9) 7f 32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size Ft spacing, Ft pipe size on line 12, max perfs/lateral = 30 > line #8 must be less > OK <br />10) 4A doses per day (4 minimum) <br />1 i) E 1707 gallons per dose (treatment volume) <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />13) 15 feet of 2.0 inch supply line leads to ®gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 153 gallons TOTAL pump out volume (treatment + drainback) <br />)s) 8 feet vertical lift from pump to mound laterals, leads to a: <br />16) 29 GPM @ 14 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 9250 gal Dose tank (design size / LUG req'd) at 25.49 19pi <br />leads to a: I Optional Time dosing of: <br />18) 6.0 inch swing on Demand float, (this delivers Average flow, =70% of Peak design flow) <br />5.3 min ON <br />19) 12 inches from bottom of tank to "Pump OFF" float 8.5 hrs OFF <br />24) 18 1 inches from bottom of tank to "Pump ON" float 12 inches to "Timer ON" float <br />21) 1 21 linches from bottom of tank to "Hi Level" float 31 inches to "Hi Level" float <br />22) 715 gallons reserve capacity (after High Level Alarm is activated -demand dosed) <br />
The URL can be used to link to this page
Your browser does not support the video tag.