My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
710 Lakeview Parkway - 06-117-23-34-0014
>
Land Use
>
Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:35 PM
Creation date
10/21/2021 9:17:36 AM
Metadata
Fields
Template:
x Address Old
House Number
710
Street Name
Lakeview
Street Type
Parkway
Address
710 Lakeview Pkwy
Document Type
Land Use
PIN
0611723340014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/1U LaKeview Fla rKway <br />F7 WELL setbacks: 20'- 50' to sewer Line req's MDH pressure test form (5 psi for 15 min) <br />50' to everything 900' to drainfield with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE /BLUFF setback: 20' for bluff. Lakes: GD _, RD—, NE Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />Sewer line Et tank connection (no hard 90's, long sweep 90 or 2-45's, slope minimum 1" in 8' = 1%) <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight risers, baffles, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons Multiple tanks or compartments req'd <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank, risers and piping (water tight risers, insulated, proper depth, drainback) <br />mfg 1250 gallons <br />Optional Time dosing of: <br />dose pump 36 gpm 19 head VERIFY PUMP CURVE 5.5 min ON 8.5 hr OFF <br />verify that installed "vertical lift from pump to laterals" is no more than design value of 11 feet <br />float setting drop 7.8 inches at25.5 gpi "DESIGNED" 4.9 inches approx float tether length <br />199.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 K 62.5 <br />Sand lift depth 24 inches. (Jar test : 2" sand leaves < 1 /8" silt after 30 min) <br />0 Absorption sand beyond rock 0.0 upslope 17.0 downslope <br />Bermed topsoil beyond rockbed 12 upslope 14 sideslope 28 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe fit fittings) <br />3.0 ft lateral spacing <br />e 7132 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary �Re-use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.