My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-29-2021 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2720 White Oak Cir - 04-117-23-42-0020
>
Septic
>
07-29-2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:13 PM
Creation date
10/20/2021 3:30:46 PM
Metadata
Fields
Template:
x Address Old
House Number
2720
Street Name
White Oak
Street Type
Circle
Address
2720 White Oak Cir
Document Type
Septic
PIN
0411723420020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: Multiple tanks or compartments req'd <br />pub Larger tame witin muitipie comer Lanrcs <br />1000 gallon Dose tank (minimum) at 25,00 gpi <br />29 GPM C 17 ft. of head, Pump required <br />6.0 inch swing on Demand float which translates to roughly 4.0 inches of float tether length <br />Optional Time dosing of: <br />N31' <br />minutes ON <br />18 inches from bottom of tank to "pump ON" float, or hours OFF <br />21 inches from bottom of tank to "Hi Level Alarm" or inches to "timer ON" float <br />inches to "Hi level" float <br />252 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />24 inch, or 2.0 ft. Sand Lift Mound <br />10.0 ft. wide by 50.0 ft. long Rock bed <br />3 laterals 2,00 inch diameter 48.0 ft. long3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out ft valve box assemblies <br />20.0 ft.Total sand ABSORPTION width (minimum) <br />OA ft. upslope and sideslope (sand beyond rockbed, minimum) <br />10,0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 13 ft. upslope berm <br />4:1 sideslope 18 ft. sideslope berms <br />4:1 downslope 24 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />berm 13 I i, DownsloDe berm 24 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />2.0 I I Glean sand lift <br />_ _ 1.0 Depth to Limiting <br />Limiting Condition "—_--_____-- <br />Absor—vtionWidth 20.0 ----o—_ ..--- <br />Note: <br />For O to 1% slopes, Absorption Width is measured from the Bedequally in bath directions. <br />For slopes ,l%, Absorption Width is measured downhill from the upslope edge of the Bed <br />Rock Bed: 17.0 yd3 or *1.4= 24 ton 6 inches under pipe <br />Mound Sand: 243 yd3 or *1.4= 340 ton calculation based on 3:114:1 slope from top of rockbe <br />Loamy Cap: 79 yd3 or *1.4= 111 ton 6" deep <br />Topsoil: 90 yd3 or *1.4= 126 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />
The URL can be used to link to this page
Your browser does not support the video tag.