My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
730 Lakeview Parkway - 06-117-23-34-0013
>
Septic
>
Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:34 PM
Creation date
10/20/2021 3:24:30 PM
Metadata
Fields
Template:
x Address Old
House Number
730
Street Name
Lakeview
Street Type
Parkway
Address
730 Lakeview Pkwy
Document Type
Septic
PIN
0611723340013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />1500 gallon Septic tank (minimum) Tank options: none <br />auto urger rdnK warn rnurripte comp/ ran KS <br />1250 gallon Dose tank (minimum) at 25,49 gpi <br />21 GPM C 20 ft. of head, Pump required <br />4.9 inch swing on Demand float which translates to roughly 3.5 inches of float tether length <br />if time dosing is required - 6minutes ON time Et ®hours OFF time <br />17 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />20 inches from bottom of tank to "Hi Level Alarm" or 1 30 linches to "Hi level alarm" if time dosed <br />75 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />20 inch, or 1.7 ft. Sand Lift Mound <br />10A ft. wide by 37.5 ft. long Rock bed <br />3 laterals 2.00 inch diameter 35.5 ft. long =ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out & valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17,0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />3;1 sideslope 1 14 Ift. sideslope berms <br />3:1 downslope 1 35 ft, downslope berm <br />Upslope berm = <br />I 1.7 <br />Limiting Condition — <br />4" inspection pipe <br />r— 18" cover on top <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />Clean sand lift:::� <br />Depth to limiting <br />-- <br />Absorption Width 27.(} _®__�__—�--------_Y--- <br />Note: <br />For 0 to 1% slopes, Adsorption Wldth is measured from the Bedequally in both directions. <br />For slopes >1%, Ahsnrptfon !Width is measured downhill frim the upslope edge of the Bed. <br />Rock Bed: 13.0 yd or *1.4= 18 ton 6 inches under pipe <br />Mound Sand: 213 yd or *1.4= 298 ton calculation based on 3:1/4:1 slope from top of rockbe <br />Loamy Cap; 70 yd or *1.4= 98 ton 6" deep <br />Topsoil: 81 A3 or *1.4= 113 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />/JU <_aKeview NarKway <br />
The URL can be used to link to this page
Your browser does not support the video tag.