My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Lighting Plan 10-24-2001 - Medina Electric
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2040 Wayzata Boulevard West - 34-118-23-21-0036 - (Orono HRA)
>
Land Use
>
2040 Wayzata Blvd Land Use - Dunbar
>
Dunbar Project 2000 - File Cabinet 1
>
Lighting Plan 10-24-2001 - Medina Electric
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:55:42 PM
Creation date
10/20/2021 1:49:34 PM
Metadata
Fields
Template:
x Address Old
House Number
2040
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2040 Wayzata Boulevard West
Document Type
Land Use
PIN
3411823210036
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STEEL SQUARE POLES <br /> STEEL Steel Square Poles from LSI Lighting Systems offer durable aesthetics to enhance your <br /> specified lighting design. For a look that lasts, specify LSI poles. <br /> SQUARE SPECIFICATIONS <br /> POLES POLE SHAFT BASE GROUND LUG <br /> Pole shaft is electro-welded Pole base is ASTM-A36 hot-rolled Ground lug is standard. <br /> ASTM-A500 Grade C steel tubing steel plate with a minimum yield DUPLEX RECEPTACLE <br /> with a minimum yield strength strength of 36,000 psi.Two-piece <br /> SON- SQBO- of 50,000 psi.On Tenon Mount square base cover is optional. Weatherproof duplex receptacle <br /> 2.3/8"0.0. Bolt-On is optional. <br /> x 4-3/4" Mount, steel poles,tenon is 2-3/8"O.D. <br /> Tenon 2-Bolt high-strength pipe.Tenon is 4- ANCHOR BOLTS GROUND FAULT <br /> Pattern 3/4"in length.Straight poles are Poles are furnished with anchor CIRCUIT INTERRUPTER <br /> 4",5",and 6"square. bolts featuring zinc-plated double <br /> nuts and washers.Galvanized Ground fault circuit interrupter <br /> HAND-HOLE anchor bolts are optional.Anchor is optional. <br /> Standard hand-hole location is bolts conform to ASTM A36 with FINISHES <br /> 12"above pole base.Hand hole a minimum yield strength of Each pole is finished with DuraGrip', <br /> size is 2"x 4". Poles 22'and 36,000 psi. LSI Lighting Systems'revolutionary <br /> SQP- above have a 3"x 6"reinforced superior baked-on polyester-powder <br /> SqPole <br /> Topre hand hole. finishingprocess,togivethe ole an <br /> Pole P <br /> ® exceptionally attractive appearance. <br /> STEEL SQUARE POLES The process electrostatically applies <br /> 5" and 6" steel square poles) and thermally fuses a polyester <br /> POLE SELECTION CHART (4", <br /> powder to the pole.This unique <br /> 14'39' sql- Height EPA' Outside Material Bolt protection process provides an <br /> No 70 MPH 80 MPH 90 MPH 100 MPH Dimensions Circle <br /> Mounting14' 23.3 16.7 12.2 9.0 4" 511G B extremely smooth and uniform <br /> Holes 16' 18.6 13.1 9.3 6.5 a S11G B finish which withstands extreme <br /> 16' 34.6 25.0 18.5 <br /> I <br /> 18' 14.4 9.7 6.5 <br /> 13.8 5' S11G c weather changes without cracking <br /> 4.2 4' S11G B or peeling.DuraGrip finish features <br /> 18' 27.9 19.7 14.1 10.1 5' S11G <br /> c a two-year limited warranty. <br /> 20' 11.0 7.0 4.2 2.2 4" S11G B Standard finish colors available for <br /> 20' 18.7 12.8 8.8 5.9 4' SO7G B are bronze,black,platinum <br /> 20' 22.5 15.4 10.5 7.0 5' 511G c poles <br /> SF- 20' 35.5 25.4 18.4 13.4 5" SO7G D plus,buff,white,and green. <br /> Single 22' 10.4 6.3 3.4 1.4 4' S11G B Optional DuraGrip' Plus features <br /> Flood Pole 22' 18.7 12.6 8.4 5.4 4' SO7G B <br /> Preparation 22' 20.8 13.8 8.9 5.5 5• S11G c added protection with a 3.0 to 5.0 <br /> 22' 34.0 23.9 17.0 12.0 5' SO7G D mil thickness of polyester-powder <br /> 7.7 4.0 1.s - 4 sjjG B finish plus an inner coating.This <br /> 24 „fsT" . SO7G B specially developed inner coating <br /> 24' is a thermal plastic hydrocarbon <br /> 24' 22.5 14.9 9.7 5.9 5• S11H' D resin applied 28.6 19.6 13.4 8.9 5' SO7G o t0 the inside of the <br /> 24' 46.2 32.6 23.2 16.6 6' SO7G J pole to seal and protect against <br /> 26' 5.3 2.1 - - 4' 511G B atmospheric and corrosive matter. <br /> 26' 12.0 7.2 3.9 1.5 4• 5070 B DuraGrip Plus finish features a <br /> 26' 13.2 7.6 3.8 1.0 5• S11G c five-year limited warranty. <br /> 26' 24.0 15.8 10.3 6.3 5• SO7G D <br /> 26' 39.6 27.3 18.9 12.9 6' SO7G J <br /> 30' 16.3 9.6 5.0 1.7 5' SO7G D <br /> 30' 28.8 18.6 11.6 6.6 6" SO7G J <br /> 35' 18.3 10.0 4.3 6' SO7G J <br /> 39' 11.5 4.3 - - 6' SO7G J <br /> Hand-hole Refer to EPA data sheet for complete EPA information '-H•denotes high yield steel(70,000 psi). <br /> 12" <br /> Optional Standard <br /> Base Cover <br /> Follow these steps to determine the luminaire/pole combination for your application. <br /> • Select luminaire from Luminaire • Refer to Luminaire EPA Chart ' Select MPH to match the wind speed in <br /> Projection (4)w. Ordering Information. to determine EPA value. the application area. <br /> a 1 '` Anchor • Select bracket configuration. • Select Height of pole. • Confirm the pole EPA that is equal to or <br /> Bolts exceeds the luminaire/bracket EPA as was <br /> previously determined. <br /> Foundation <br /> By Other <br /> k • <br /> i <br /> Lighting Systems' <br /> ©LSI Industries Inc. REV 2/01 10000 Alliance Road • Cincinnati,Ohio 45242♦ (513)793-3200 FAX(513)984-1335♦ www.lsi-industries.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.