My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-26-2021 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
460 Lakeview Parkway - 06-117-23-32-0015
>
Septic
>
05-26-2021 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:49 PM
Creation date
10/20/2021 12:59:49 PM
Metadata
Fields
Template:
x Address Old
House Number
460
Street Name
Lakeview
Street Type
Parkway
Address
460 Lakeview Pkwy
Document Type
Septic
PIN
0611723320015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
46U LaKeview F°arKway <br />WELL setbacks: 20'- 50' to sewer line req's MDH pressure test form (5 psi for 15 min) <br />50' to everything 100' to drainfield with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE f BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE Protected wetland _. <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />❑ Sewer line Et tank connection (no hard 90's, long sweep 90 or 2-45's, slope minimum 1" in 8' = 1%) <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />❑ Septic tank and risers (water tight risers, baffles, insulated, proper depth, existing verified by pumping) <br />Mfg 2250 gallons Multiple tanks or compartments req'd <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter & alarm <br />Dose tank, risers and piping (water tight risers, insulated, proper depth, drainback) <br />Mfg----- 1250 gallons <br />Optional Time dosing of: <br />dose pump 36 gpm 13 head VERIFY PUMP CURVE 5.3 min ON 8.5 hr OFF <br />verify that installed "vertical lift from pump to laterals" is no more than design value of 7 feet <br />float setting drop 4.6 inches at 41.7 gpi "DESIGNED" 3.3 inches approx float tether length <br />192.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 118"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 63.0 <br />Sand lift depth 24 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />❑ Bermed topsoil beyond rockbed 10 upslope 17 sideslope 42 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe & fittings) <br />3.0 ft lateral spacing <br />F <br />7/32 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary <br />monitoring plan and type <br />well abandonment form - if necessary <br />�Re-use existing tank certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.