My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2-27-20 Septic Design and Plans
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
3250 Fox Street - 05-117-23-44-0012
>
Septic
>
2-27-20 Septic Design and Plans
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:22:47 PM
Creation date
10/6/2021 11:00:53 AM
Metadata
Fields
Template:
x Address Old
House Number
3250
Street Name
Fox
Street Type
Street
Address
3250 Fox St
Document Type
Septic
PIN
0511723440012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mo u n d Design <br />www.SepticResauree.cam (vers 15.2) <br />Property Owner: Martin Lueck <br />Site Address: 3250 Fox Street <br />Comments: <br />Date: 3/27/2020 <br />PID: 0511723440012 <br />instructions: = = enter data 0 = adjust if desired = = computer calculated - DO NOT CHANGE! <br />1) bedroom Type Residential System <br />2) 600 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2000 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of F12 req's a min 50 ft. long rockbed <br />6) 10.0 ft rockbed width 50.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing. (maximum of 3 for both) <br />end feed manifold connection <br />8) laterals 48.0 feet long 17.0 perfs / lateral 51 perfs total <br />(1 /2 a pert means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs atfeet residual head gives 0.56 gpm flow rate per perforation <br />for this pert size Fr spacing, It pipe size on line 12, max perfs/lateral = 30 line #8 must be less > OK <br />)o) 4.0 doses per day (4 minimum) <br />11) 150 gallons per dose (treatment volume) <br />2.00 5x <br />i2) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />33) 403 feet of 2.D inch supply line leads to =galLons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 219 gallons TOTAL pump out volume (treatment + drainback) <br />is) 39 feet vertical lift from pump to mound laterals, leads to a: <br />16) 29 GPM @ 56 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />leads to a <br />18) 8.6 inch swing on Demand float, or timed dosing of7.6 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) 9 hrs OFF test and adjust as necessary) <br />19) 12 inches from bottom of tank to "Pump OFF" float <br />20) 1 21 linches from bottom of tank to "Pump ON" float, orM34 <br />inches to "Timer ON" float if time dosed <br />21) 24 inches from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) 638 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.