9-13-18 Septic Design
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
3565 Sixth Ave N - 29-118-23-43-0003
>
Septic
>
9-13-18 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:27:01 PM
Creation date
10/6/2021 9:33:02 AM
Metadata
Fields
Template:
x Address Old
House Number
3565
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
3565 6th Avenue North
Document Type
Septic
PIN
2911823430003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />atm urger ianK wim MUMpte comer ranKs <br />1250 gallon Dose tank (minimum) at EDP' <br />36 JGPM @ 25 ft. of head, Pump required <br />8.1 inch swing on Demand float which translates to roughly 5.1 inches of float tether length <br />if time dosing is required -->5.8 minutes ON time li ®hours OFF time <br />20 inches from bottom of tank to "pump ON' float, or 12 1 Inches to 'timer Ohl' float <br />23 linches from bottom of tank to "Hi Level Alarm' or 133 Inches to 'Hi level alarm' if time dosed <br />=ft. of 2.Q inch supply Linc with end feed manifold connection <br />(Tip: "top feed' manifold to control drainback) <br />18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 Inch diameter =ft. Long =ft. lateral spacing <br />7/32 inch perfs 3.0 ft, perforation spacing <br />No lEfftuent filter & atarm <br />3 clean out ii valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sidestope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upstope ratio91ft. <br />ft. upslope berm <br />3:1 sidestope ft. sidestope berms <br />4:1 downslope downstope berm <br />4" inspection pipe <br />18" cover on top <br />berm 11 .IT 1� V Downstoae bean 23 <br />12" cover on sides <br />(6'" loamy cap & 6" topsoa) <br />1.5 Glean sand lift <br />_ _ 1`5 Depth to Limiting <br />Limiting Condition--------------.—_—�— <br />I Absorption Width <br />27.0 —~_ <br />Mote: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Abwrptton Wdth is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 yd3 or `1.4= 29 ton <br />Mound Sand: 203 yd3 or *1.4= 284 ton <br />Loamy Cap: 76 yd3 or "1.4- 106 ton <br />Topsoil: 88 yd' or *1.4- 123 ton <br />Inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe( <br />6' deep <br />6' deep <br />