My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8-7-20 Septic Design
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
3280 Fox Street - 05-117-23-44-0011
>
Septic
>
8-7-20 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:22:43 PM
Creation date
10/5/2021 4:02:09 PM
Metadata
Fields
Template:
x Address Old
House Number
3280
Street Name
Fox
Street Type
Street
Address
3280 Fox St
Document Type
Septic
PIN
0511723440011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />®gallon Septic tank (minimum) Tank options: none <br />oum Larger tank vnm mutupte comp/canm <br />2000 1gaLlon Dose tank (minimum) at 48.20 gpi <br />56 GPM @ 26 ft. of head, Pump required <br />4.2 inch swing on Demand float which translates to roughly 3.1 inches of Float tether length <br />if time dosing is required - 3.6 .mutes ON time B =hours OFF time <br />22 inches from bottom of tank to "pump ON" float, or 1 18 linches to -timer ON" float <br />25 inches from bottom of tank to "Hi Level Alarm" or 1 35 linches to "Hi level alarm" if time dosed <br />185 ft. of =inch supply line with middle feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />R <br />inch, or2.0 ft. Sand Lift Mound <br />ft.wide by 100.0 ft. long Rock bed <br />laterals 1.50 inch diameter 490 f . long 30 f . lateral spacing <br />inch perfs F3.0 ft. perforation spacing <br />No I Effluent filter Et alarm <br />6 Iclean out ft valve box assemblies <br />40.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />30.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios ive BERM widths (topsoil beyond rockbed) of: <br />3:1 upstope ratio 7 ft. udesto berm <br />3:1 sidestope 17 ft. sideslope berms <br />4:1 downslope 53 ft. downslope berm <br />�4"inspection pipe <br />— W cover on top <br />12" cover on sides <br />(6" k,=ycep &6" toproQ <br />/1 2.0 JjClean sand lift <br />1.0 Depth to Limfting <br />Limiting Condi[icc — ------ _______ <br />•6enmfinn W;Akk 40.D <br />Note: <br />For 0 to 1% slopes, Absorption Wtdth is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Wdth is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 45.0 yds or'1.4= 63 ton 9 inches under pipe <br />Mound Sand: N212 <br />yds or'1.4= 1144 ton calculation based on 3:1/4:1 slope from top of rockbe• <br />Loamy Cap: yds or *1.4- 272 ton 6" deep <br />Topsoil: ydsor'1.4= 297 ton 6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.