08-19-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
D
>
Deborah Drive
>
415 Deborah Drive - 31-118-23-24-0007
>
Septic
>
08-19-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:25 PM
Creation date
10/5/2021 2:13:55 PM
Metadata
Fields
Template:
x Address Old
House Number
415
Street Name
Deborah
Street Type
Drive
Address
415 Deborah Drive
Document Type
Septic
PIN
3111823240007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
201 purple code Mound Design "" <br />Property Owner: Nora SiLLerud <br />Site Address: 415 Deborah Dr. Orono <br />Comments: <br />Date: 8/4/2019 <br />PID: <br />:tions: O =enter data O = adjust if desired = = computer calculated - DO NOT CHANGE! <br />=bedroom Type �I Residential System <br />750 JGPD design flow <br />No Garbage disposal or pumped to septic <br />2250 Gal Septic tank (code minimum) <br />2250 Gal Septic tank (design size / LUG read) <br />Tank options: none <br />s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br />10.0 ft rockbed width F62.5 ft rockbed length <br />3.0 ft perforation spacing (maximum of 3 for both) <br />7) =ft lateral spacing <br />end feed manifold connection <br />a) =laterals 60.5 feet long 21.0 perfs / lateral 63 perfs total <br />(1/2 a pert means the first perf starts at the middle feed manifold) <br />9) i/4" inch perfs at =feet residual head gives 0.74 gpm flow rate per perforation <br />for this perf size Et spacing, Ft pipe size on line 12, max perfs/lateral = 25 , line #8 must be less - OK <br />107 4.0 doses per day (4 minimum) <br />11) 188 gallons per dose (treatment volume) <br />2.00 5x <br />e) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />l;1 40 feet of 2.0 inch supply line leads to =7 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />w) F 195 gallons TOTAL pump out volume (treatment+ drainback) <br />117 10 feet vertical lift from pump to mound laterals, leads to a: <br />16) 47 GPM @ =feet of head, Pump requirement (note: >50gpm may require an extra 3-6of head) <br />gal Dose tank (design size /LUG req d) at F26.00gpi <br />17) F12570gaL Dose tank (code minimum) F1250 <br />Leads to a <br />18) =inch swing on Demand float, or timed dosing of 4.1 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) 9 hrs OFF test and adjust as necessary) <br />19) 12 inches from bottom of tank to "Pump OFF' float <br />20) 20 inches from bottom of tank to "Pump ON" float, or12 inches to "Timer ON" float if time dosed <br />21) 23 inches from bottom of tank to "Hi Level" float, or 33 inches to "Hi Level" float if time dosed <br />22) 652 gallons reserve capacity (after High Level Alarm is activated) <br />