My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
08-19-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
D
>
Deborah Drive
>
415 Deborah Drive - 31-118-23-24-0007
>
Septic
>
08-19-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:25 PM
Creation date
10/5/2021 2:13:55 PM
Metadata
Fields
Template:
x Address Old
House Number
415
Street Name
Deborah
Street Type
Drive
Address
415 Deborah Drive
Document Type
Septic
PIN
3111823240007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
41] Deborah Ur. Orono INSPECTOR CHECKLIST - mound <br />El WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />10' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10'to everything <br />Road setback: platted: 10' prop line. Metes Ft bounds: out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE _ Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure se 10' to bed,tank & sewer line. (else sewer line > 12" below) <br />ElSewer line & baffle connection (no 9D's, T between 45's, slope min 1"in 8', max 2"in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />Mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter & alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfg 1250 gallons <br />dose pump 47 gpm 18 head VERIFY PUMP CURVE 4.1 min ON 9 hr OFF <br />❑ float setting drop 7.5 inches at 26.0 gpi "DESIGNED" 4.8 inches approx float tether length <br />195.0 gal dose divided by gpi "INSTALLED" = _inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1 /8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+, <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 62.5 <br />Sand lift depth 14 inches. (Jar test : 2" sand leaves � 1 /8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />❑ Bermed topsoil beyond rockbed 10 upstope 16 sideslope 23 downstope <br />cover depth of 12-18"t VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe & fittings) <br />3.0 It lateral spacing <br />e 1/4" inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />s <br />Abandon existing system - if necessary <br />monitoring plan and type <br />well abandonment form - if necessary <br />=Re -use existing tank certification <br />