My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-08-2020 Septic Design
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4725 Augusta Street - 06-117-23-32-0008
>
Septic
>
07-08-2020 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:41 PM
Creation date
10/5/2021 12:59:03 PM
Metadata
Fields
Template:
x Address Old
House Number
4725
Street Name
Augusta
Street Type
Street
Address
4725 Augusta St
Document Type
Septic
PIN
0611723320008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />DU70 Larger rank cairn MUMPLe comps ranKS <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />36 JGPM @ 15 ft. of head, Pump required <br />7.6 inch swing on Demand float which translates to roughly 4.8 inches of float tether length <br />uptionat i ime aosing or: <br />a.4 minutes uN <br />20 inches from bottom of tank to "pump ON" float, or 8.5 hours OFF <br />23 inches from bottom of tank to "Hi Level Alarm" or 12 inches to "timer ON" float <br />33 inches to "Hi level" float <br />35 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter ft alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 11 ft. upslope berm <br />3:1 sideslope 1 13 Ift. sideslope berms <br />4:1 downslope 1 25 ft. downslope berm <br />4" inspection pipe <br />T18" cower on top <br />berm 1 .I 1� i,, pownslooe berm z5 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.5 i [Clean sand lift <br />Depth to Limiting <br />Limr`ting i~ondition — — <br />Absorotion Width 27 0 � — � — � — <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption 1'Widtti is measured downhill from the upslope edge of the Bed <br />Rock Bed: 21.0 yda or *1.4= 29 ton <br />Mound Sand: 217 yd or *1.4= 304 ton <br />Loamy Cap: 80 yd or *1.4= 112 ton <br />Topsoil: 91 yd or *1.4= 127 ton <br />INSPECTOR CHECKLIST <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe <br />6" deep <br />6" deep <br />- mound <br />
The URL can be used to link to this page
Your browser does not support the video tag.