10-23-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
Wear Lane North
>
155 Wear Lane North - 33-118-23-34-0013
>
Septic
>
10-23-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:50:54 PM
Creation date
10/5/2021 11:23:03 AM
Metadata
Fields
Template:
x Address Old
House Number
155
Street Name
Wear
Street Type
Lane
Street Direction
North
Address
155 Wear Lane North
Document Type
Septic
PIN
3311823340013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
View images
View plain text
Installer Summary <br />2500 gallon Septic tank (minimum) Tank options: Multiple tanks or compartments req'd <br />1250 gallon Dose tank (minimum) at 29.06 gpi <br />47 GPM 22 ft. of head, Pump required <br />6.8 inch swing on Demand float which translates to roughly 4.4 inches of float tether length <br />if time dosing is required --> 4.2 minutes ON time ft F9 hours OFF time <br />23 inches from bottom of tank to "pump ON" float, or 16 inches to "timer ON" float <br />26 inches from bottom of tank to "Hi Level Alarm" or 36 inches to "Hi level alarm" if time dosed <br />®ft. of 2.0 inch supply tine with end feed manifold connection <br />(Tip:"top feed" manifold to control drainback) <br />Minch <br />inch, or oft. <br />ft. Sand Lift Mound <br />ft. wide by ft. long Rock bedlaterals inch diameter 60.5 ft. long 3.0 ft. lateral spacing <br />perfs perforation spacing <br />No Effluent filter ti alarm <br />3 clean out 8: valve box assemblies <br />20.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />10.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />Mdownstope <br />upslope ratio 13 ft. upslope berm <br />sidestope 18 ft. sideslope berms 24 ft. downslope berm <br />berm 13 <br />2.0 <br />Lirn►ting Condition <br />inspection pipe <br />— 18" cover on top <br />Clean sand lift <br />Depth to Limiting <br />- - Absorption Width 20.0 <br />berm = <br />12" cover on sides <br />(6' loamy cap & 6' topvD* <br />Note <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 yd3or•1.4= 29 ton <br />Mound Sand: 282 yd3or'1.4= 395 ton <br />Loamy Cap: 91 yd or *1.4= 127 ton <br />Topsoil: 103 yd or `1.4= 144 ton <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbei <br />6" deep <br />6" deep <br />