My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-23-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
Wear Lane North
>
155 Wear La N - 33-118-23-34-0013
>
Septic
>
10-23-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:50:54 PM
Creation date
10/5/2021 11:23:03 AM
Metadata
Fields
Template:
x Address Old
House Number
155
Street Name
Wear
Street Type
Lane
Street Direction
North
Address
155 Wear Lane North
Document Type
Septic
PIN
3311823340013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www SepticResource.com (vers 15.2) <br />Property Owner: Ross Johnson <br />Site Address: 155 Wear Ln. <br />Comments: <br />instructions: = = enter data = adjust if desired <br />11 =bedroom Type Residential <br />z) 750 GPD design flow <br />11 No Garbage disposal or pumped to septic <br />Date: 10/15/2018 <br />PID: 3311823340013 <br />= = computer calculated - DO NOT CHANGE! <br />System <br />1500 Gat Septic tank (code minimum) 2500 Gat Septic tank (design size / LUG req'd) <br />Tank options: Multiple tanks or compartments req'd <br />1.2 GPD/ftz mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br />10.0 ft rockbed width 62.5 ft rockbed length <br />3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />laterals 60.5 feet long 21.0 perfs / lateral 63 Jperfs total <br />(1 /2 a pert means the first pert starts at the middle feed manifold) <br />EEKI inch perfs at =feet residual head gives 0.74 gpm flow rate per perforation <br />for this pert size li spacing, E& pipe size on line 12, max perfs/lateral = 25 line #8 must be less > <br />101 4.0 doses per day (4 minimum) <br />111 188 gallons per dose (treatment volume) <br />2.00 5x <br />121 2.00 inch diameter laterals must be used to meet 'Ax pipe volume' requirement <br />2.00 3x <br />131 60 feet of 2.0 inch supply line leads to 10 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />141 198 gallons TOTAL pump out volume (treatment + drainback) <br />151 M47 <br />feet vertical lift from pump to mound laterals, leads to a: <br />161 GPM @ 22 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />121 750 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 29.06 gpi <br />leads to a <br />181 6.8 inch swing on Demand float, or timed dosing of 4.21hrs <br />min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) 9 OFF test and adjust as necessary) <br />19)16 inches from bottom of tank to "Pump OFF' float <br />20) 23 inches from bottom of tank to "Pump ON" float, or [��36 <br />6 inches to 'Timer ON" float if time dosed <br />211 26 inches from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) 494 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.