My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-18-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
160 Big Island - PID: 23-117-23-23-0020/0019
>
Septic
>
10-18-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:35 PM
Creation date
10/5/2021 11:13:58 AM
Metadata
Fields
Template:
x Address Old
House Number
160
Street Name
Big Island
Address
160 Big Island
Document Type
Septic
PIN
2311723230020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br />16U big island <br />ElWELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE I BLUFF setback: 20' for bluff. Lakes: GD _, RD — NE Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATERLINE under pressure se 10' to bed,tank Ft sewer line. (else sewer linen 12" below) <br />Sewer line Et baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />Mfg 1000 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfg 1000 gallons <br />dose pump 14 gpm 23 head VERIFY PUMP CURVE 4.7 min ON 9 hr OFF <br />El float setting drop ##### inches at gpi "DESIGNED" ##### inches approx float tether length <br />66.0 gat dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />20 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box I control panel f electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 19.0 <br />Sand lift depth 18 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 16.9 downslope <br />Bermed topsoil beyond rockbed 10 upslope 11 sidestope 20 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />e 114" inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary �Re-use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />