10-18-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
160 Big Island - PID: 23-117-23-23-0020/0019
>
Septic
>
10-18-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:12:35 PM
Creation date
10/5/2021 11:13:58 AM
Metadata
Fields
Template:
x Address Old
House Number
160
Street Name
Big Island
Address
160 Big Island
Document Type
Septic
PIN
2311723230020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www.SegtiCResource.com !vers 15.21 <br />Property Owner: Ann Behning Date: 10/10/2018 <br />Site Address: 160 Big Island PID: 2311723230020 <br />Comments: Classification II Cabin <br />instructions: = = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />t) bedroom Type L� Residential System <br />2) 225 GPD design flow <br />3) No Garbage disposal or pumped to septic <br />4) Gal Septic tank (code minimum) 1000 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of =req's a min 18.8 ft. long rockbed <br />6) 10.0 ft rockbed width 14.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />Lend feed manifold connection <br />8) I !laterals 17.0 feet long 6.0 perfs / lateral 18 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />g) 1 /4"° inch perfs at feet residual head gives 0.74 gpm flow rate per perforation <br />for this perf size Et spacing, It pipe size on line 12, max perfs/lateral = 25 , line #8 must be less > OK <br />10) 4.0 doses per day (4 minimum) <br />11) 56 gallons per dose (treatment volume) <br />2.00 5x <br />i2) Z.00 inch diameter laterals must be used to meet "4x pipe volume' requirement <br />2.00 3x <br />33) 6D feet of 2.0 inch supply line leads to =gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) b6 gallons TOTAL pump out volume (treatment + drainback) <br />ts) 17 Ifeet vertical lift from pump to mound laterals, leads to a: <br />16) 14 GPM @ 23 feet of head, Pump requirement (note: >50gpm may require an extra 3.6' of head) <br />E7) 225 gal Dose tank (code minimum) i000 gal Dose tank (design size / LUG req'd) at gpi <br />Leads to a <br />18) ###### inch swing on Demand float, or timed dosing of4.7 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) hrs OFF test and adjust as necessary) <br />�9) 12 inches from bottom of tank to "Pump OFF" float <br />20) ###### inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON" float if time dosed <br />20 ###### inches from bottom of tank to "Hi Level" float, or ##### inches to "Hi Level" float if time dosed <br />22) ###### gallons reserve capacity (after High Level Alarm is activated) <br />